CONTACTOR CONFIGURATION
Phase Rotation Sensor
E-326 1 Amp, 115 VAC
PRODUCT SPECIFICATIONS
Construction
Epoxy Encapsulated
Operating Voltage and Frequency
Continuous Duty, 115V, 3 Phase, L to N, 400 Hz
Max. Input Voltage Range for Normal Operation
115
±20V
Operation
The phase rotation sensor will apply a DC potential of
+28V to any external relay coil or load when the phase
rotation is A-B-C and shall remove the +28V signal
when phase rotation is other than A-B-C.
Normal Load
1 Amp Continuous
5 Amps Intermittent (.020 Second Maximum)
Environmental:
Temperature Operating
-55
°C to +71°C
Vibration
.060 DA 5 to 55 Hz
Acceleration
55 - 200 Hz Log Constant
Weight
4.5 Oz.
Features:
Controls External Relay
Epoxy Encapsulated
115 VAC, 400 Hz, 3 Operation
1 Amp
High Reliability
Meets many requirements of MIL-R-6106
Light Weight Construction
Notes:
Catalog (web doc only)
Dimensions are in inches and
Dimensions are shown for
USA: 1-800-522-6752
South America: 55-11-3611-1514
Revised 5-04
millimeters unless otherwise
reference purposes only.
Canada: 1-905-470-4425
Hong Kong: 852-2735-1628
specified. Values in brackets
Specifications subject
Mexico: 01-800-733-8926
Japan: 81-44-844-8013
www.tycoelectronics.com
are metric equivalents.
to change.
C. America: 52-55-5-729-0425
UK: 44-141-810-8967
HARTMAN Aerospace Power Products
Dimensions for this product are expressed in inches.
Multiply values by 25.4 for millimeters.
For factory-direct application assistance, contact the HARTMAN
product team at (419) 521-9500, Fax (419) 526-2749.
2004 by Tyco Electronics Corporation. All Rights Reserved.
HARTMAN and TYCO are trademarks.