DC/DC CONVERTERS
40W High Efficiency DC/DC Converters
1
2 YEAR WARRANTY
EXA40 Series
Single output
High efficiency topology, 91% typical at 5V
Approved to EN60950, UL1950, CSA C22.2 No. 234/950
Operating ambient temperature of -40°C to +70°C
(natural convection)
Complies with ETS 300 019-1-3/2-3
Complies with ETS 300 132-2 input voltage and current
requirements
Fully compliant with ETS 300 386-1
The EXA40 Series, comprising 8 different models is targeted specifically at the
telecommunications, industrial electronics, mobile Telecommunications and distributed
power markets. The series offers two wide input voltage ranges of 18-36VDC and
36-75VDC. Typical efficiencies are 91% for the 5V output, 88% for the 3.3V, 86%
for the 2.75V and 84% for the 1.8V. The series has been designed primarily for
Telecommunications applications and complies with ETS 300 386-1 immunity and
emission standards for high priority of service class. In addition the series complies
with ETS 300 019-1-3 environmental standards (all classes) including shock, vibration,
humidity and thermal performance. A high level of reliability has been designed into all
models through the extensive use of conservative derating criteria. Remote enable and
overtemperature shutdown are included as standard while true latching OVP is
available as an option.
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
SPECIFICATIONS
File Name: LF_EXA40.PDF Rev: 15 Jan 2002
OUTPUT SPECIFICATIONS
MINIMUM
TYPICAL
MAXIMUM
Voltage adjustability
2V75, 3V3, 5V outputs
±10%
±11%
±12%
1V8 output
+12/-17%
+13/-18%
+14/-19%
Line regulation
Low line to high line
+0.05%
+0.4%
Load regulation
Full load to no load
+0.20%
+0.4%
Output current range
0A
8A
Ripple and noise
20MHz bandwidth
50mV pk-pk
100mV pk-pk
20MHz bandwidth
10mV rms
20mV rms
Temperature coefficient
See Figure 4
±0.01%/°C
±0.02%/°C
OVP transient (See Note 6)
5V output
6.8V TVS
3V3/2V75 outputs
4.1V TVS
1V8 output
4.1V TVS
OVP latching (See Notes 1, 3)
5V output
6.0V
6.2V
6.4V
(optional)
3V3 output
4.0V
4.2V
4.4V
2V75 output
3.4V
3.6V
3.8V
1V8 output
2.4V
2.5V
2.6V
Short circuit protection (Note 5)
Continuous
Short circuit current (Note 5)
Rshort <20m
10A rms
12A rms
Transient response
Peak deviation
50% to 75% and back
100mV
150mV
Settling time
to 1.0%, no external cap
250s
400s
Current limit
Low line to high line
100%
140%
180%
Voltage accuracy
±1.0%
±1.5%
INPUT SPECIFICATIONS
MINIMUM
TYPICAL
MAXIMUM
Input voltage range
24Vin nominal
18VDC
24VDC
36VDC
48Vin nominal
36VDC
48VDC
75VDC
Input current
No load
50mA
100mA
Remote OFF, UVLO
2.5mA
4mA
Inrush current
ETS 300 132-2
UVLO turn ON voltage (Note 4)
All inputs
88%
94%
100%
UVLO turn OFF voltage (Note 4)
All inputs
77%
86%
94%
Start-up time
Nominal line
50ms
100ms