MCD10059 Rev. 1.0
Page 20 of 41
www.power-one.com
F & FC Series DC-DC Converter Input Filters
FC Series, 0-100V, 5/10/20 Amps, TH Mount
Figure 4. Differential Mode Attenuation Plot
Figure 5. Common Mode Attenuation Plot
Module: FC100V5A, five ampere EMI filter.
Instrument: Hewlett-Packard model 4194A
Start Freq: 1.0 kHz.
Stop Frequency: 100 MHz.
Scale: 10 dB per division.
System: 50 in and 50 out.
Module: FC100V5A, five ampere EMI filter.
Instrument: Hewlett-Packard model 4194A
Start Freq: 1.0 kHz.
Stop Frequency: 100 MHz.
Scale: 10 dB per division.
System: 50 in and 50 out.