26
sProduct Specifications
100V DC
150V AC/1 minute
20 cycles
1mA
Frequency: 10 to 55 Hz, single amplitude of 0.75 mm,
2 hours in each of the 3 directions.
Acceleration of 490 m/s2, 11 ms duration,
sine half-wave waveform, 3 cycles in each of the 3 axis.
96 hours at temperature of 40 and humidity of 90% to 95%
5 cycles under conditions as follows; Temperature:
-40 / 15 to 35 / 85 / 15 to 35,
Time: 30 / 5 max. / 30 / 5 max.(minutes)
Reflow: At the recommended temperature profile
Manual soldering: 350±5 for 3 seconds
Applicable FPC
t=0.17
Tin-lead plating
+0.03
-0.04
Item
1.Insulation resistance
2.
Withstanding voltage
4.Durability
(Insertion/withdrawal)
3.Contact resistance
5.Vibration
6.Shock
7.Humidity
(Steady state)
8.Temperature cycle
9.Resistance to
soldering heat
Specification
500M ohms minimum
No flashover or insulation breakdown.
50m ohms maximum
Contact resistance : 50m ohms maximum
No damage, cracks, or parts dislocation.
No electrical discontinuity of 1s or more
Contact resistance: 50m ohms maximum.
No damage, cracks, or parts dislocation.
No electrical discontinuity of 1s or more
Contact resistance: 50m ohms maximum
No damage, cracks, or parts dislocation.
Contact resistance: 50m ohms maximum
Insulation resistance: 50M ohms minimum
No damage, cracks, or parts dislocation.
Contact resistance: 50m ohms maximum
Insulation resistance: 50M ohms minimum
No damage, cracks, or parts dislocation.
No deformation of components affecting performance.
Conditions
(Note:4)
FH17L
- 30S - 0.5 SH (05)
1
2
3
4
5
6
sOrdering Information
Remarks
--------------
UL94V-0
sMaterial
Part
Contact
Metal fittings
Insulated tape
Insulator
Material
LCP
PPS
Phosphor bronze
Brass
Polyamide
Finish
--------------
Tin-lead plating
--------------
2
3
4
5
6
1
Ratings
Current rating
Voltage rating
0.4A DC
50V AC
Operating temp. range
Operatinghumidity range
-40 to +70(Note.1)
relative humidity 90% max.
(No dew-fall)
Storage temp. range
Storage Humidity range
-10 to +50(Note.2)
relative humidity 90% max.
(No dew-fall)
Note 1: Includes temperature rise caused by current flow.
Note 2: The term "storage" refers to products stored for long period of time prior to mounting and use. Operating Temperature Range and
Humidity range covers nonconducting condition of installed connectors in storage, shipment or during transportation.
Note 3. The above standards represent this series. The individual formal agreement should be based on the Specification.
Series Name
FH17
Mounting Type
None : On-Board type
L
: Offset type
LR
: Offset reverse type
Number of Contacts
8, 10, 15, 20, 24, 30
Contacts Pitch
0.5mm
Contact Style
SH : SMT horizontal mounting type
Plating specifications
Blank : Tin-lead plating
(05)
: Gold plating