Cassette Style
DC-DC Converters
M Series
Edition 01/01.2001
7/25
Electrical Output Data
General conditions
–
TA = 25
°C, unless T
C is specified.
– Connector pins 2 and 23 interconnected,
Uo = Uo nom (option P), R input not connected.
Table 4: Output data
Output
Uo nom
5.1 V
12 V
15 V
24 V
48 V
Characteristics
Conditions
min typ max
Unit
Uo
Output voltage
Ui nom, Io nom 1
5.07
5.13 11.93
12.07 14.91
15.09 23.86
24.14 47.72
48.28
V
Uo p
Output overvoltage
7.5
21
25
41
85
protection 6
Io nom Output current
Ui min...Ui max
see
Type Survey and Key Data
Io L
Output current
TC min...TC max
see Fig.
Typical output voltage Uo1 versus output currents Io
limitation response
uo
Output Switch. freq.
Ui nom, Io nom 1
15
30
25
50
35
70
40
80
50 100
mVpp
voltage
Total
IEC/EN 61204 5
60 120
40
80
40
80
40
80
-
noise
BW = 20 MHz
DUo U Static line regulation Ui min...Ui nom
±10 ±30
±12 ±50
±15 ±60
mV
Ui nom...Ui max
Io nom 1
DUo I Static load regulation Ui nom
6
25
1350
1760
3080
60 150
Io nom...0 2
DUo I c Static cross load
Ui nom
0
±15
0
±20
0
±30
0
±40
-
regulation 4
Io nom...0 3
uo d
Dynamic
Voltage
Ui nom
±220
±110
±150
±130
±150
load
deviation
Io nom
1/3 Io nom 2
td
regulation
Recovery
IEC/EN 61204
0.6
0.5
1
2
ms
time
uo d c Dynamic
Voltage
Ui nom
+10
+20
-
mV
cross load deviation
Io nom 1/3 Io nom 3
–100
–75
–140
–200
-
td c
regulation
Recovery
IEC/EN 61204
0.05
0.2
0.5
1
-
ms
4
time
0.5
0.3
0.7
2
-
aUo
Temperature
Ui min...Ui max
±0.02
%/K
coefficient
0...
Io nom
±1.0
±2.4
±3.0
±4.8
±9.6
mV/K
DUo/DTC
1 With multiple output modules, the same condition for each output applies.
2 Condition for specified output. With multiple output modules, other output(s) loaded with constant current Io nom. See fig.: Dynamic
load regulation.
3 Condition for non-specified output, individually tested, other output(s) loaded with constant current Io nom. See fig.: Dynamic load regu-
lation.
4 Multiple output modules.
5 See: Technical Information: Measuring and Testing.
6 By suppressor diode.