IEC inlet lters
FN 9222
General performance IEC inlet lter
Approvals
■
Rated currents up to 20A
■
Excellent performance/size ratio
■
Optional medical versions (B type)
■
Snap-in versions (S and S1 type)
■
Hot inlet versions (HI type)
■
Optional overvoltage protection
(Z type)
Typical applications
The FN 9222 IEC inlet filter combines an
IEC inlet and mains filter with excellent filter
attenuation in a small form factor. Choosing
the FN 9222 product line brings you the rapid
availability of a standard filter associated with
the necessary safety acceptances. Standard
IEC connector filters are a practical solution
helping you to pass EMI system approval in
a short time. A wide selection on amperage
ratings, output connections, mounting
possibilities and filters for medical applications
are designed to offer you the desired solution.
■
Exceptional conducted attenuation
performance, based on chokes with high
saturation resistance and excellent thermal
behavior.
■
Rear/front or snap-in mounting.
■
Wide mounting flanges available.
■
Optional medical versions (B type)
according to IEC/EN 60601-1.
■
12 and 15A types with hot inlet available.
■
Optional surge pulse protection.
■
Different output connections offering
maximum flexibility for assembly.
■
Custom-specific versions are available on
request.
■
Portable electrical and electronic
equipment
■
Small to medium-sized machines and
household equipment
■
Single-phase power supplies, switch-mode
power supplies
■
Test and measurement equipment
■
Medical equipment
■
Rack mounting equipment
Features and benefits
Technical specifications
Maximum continuous operating voltage:
250VAC, 50/60Hz
Operating frequency:
dc to 400Hz
Rated currents:
1 to 20A @ 50°C
Approvals by rated current:
1 to 10A (ENEC, CQC)
16A (ENEC, CQC) for 16 and 20A types
1 to 20A (UL, CSA)
High potential test voltage:
P –> E 2000VAC for 2 sec (standard types)
P –> E 2500VAC for 2 sec (B types)
P –> N 1000VAC for 2 sec (1 to 10A types)
P –> N 1100VDC for 2 sec (16 and 20A types)
Protection category:
IP40 according to IEC 60529
Temperature range (operation and storage):
-25°C to +85°C (25/85/21)
Design corresponding to:
UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939
Flammability corresponding to:
UL 94V-2 or better
Surge pulse protection (optional):
2kV, IEC 61000-4-5
MTBF @ 40°C/230V (Mil-HB-217F):
≤15A: 3,040,000 hours
≥16A: 2,256,000 hours
Typical electrical schematic
N
E
P
Line
Cx
R
2xL
2xCy
N‘
E‘
P‘
Load
Z types
Standard, R and B types
N
E
P
Line
Cx
2xL
2xCy
N‘
E‘
P‘
Load