Insulation Material
Polyester
NOMEX
TEFLON
KAPTON’
Conductor Pitch
.100
Flammability Rating
V0
Equivalent Conductor Size
24
(American Wire Gauge)
Insulation Resistance
(gnd, sig, gnd) 12 inch.
1 x 10
12
2 x 10
12
2 x 10
12
2 x 10
12
sample @ 500 VDC
Capacitance (picofarad/foot)
10.2 pF/ft
8.9 pF/ft
10.5 pF/ft
9.1 pF/ft
(gnd, sig, gnd)
Characteristic Impedance
118
123
101
112
(gnd, sig, gnd)
Temperature Rating
105° C
125° C
150° C
Current Rating
3 amps
3 amp
3 amps
Voltage Rating
300 amps
Min. Breakdown
1500 volts
Voltage @1 min
Min. Bend Radus
1/8
No Ozone Depleting Substances Are Used in the Production Processes for Flexstrip
Jumpers.
Thickness
For PCB with the
Number of
Pitch
Margin
Wire
(Pin End)
Pin Dia.
Following Diameter
Conductors
AC
Gauge
D
E
(±.001) Holes and
Recommended
(±.005) Center Tolerance
(Min. - Max.)
1.00 (.039)
.25 (.010)
28
.64 (.025)
.320 (.0126)
—
2—70
1.25 (.049)
.25 (.010)
28
.64 (.025)
.320 (.0126)
.71 (.028)
2—70
1.27 (.050)
.25 (.010)
28
.64 (.025)
.320 (.0126)
.71 (.028)
2—70
1.90 (.075)
.25 (.010)
26
.84 (.033)
.404 (.0159)
.79 (.031)
2—60
2.00 (.079)
.25 (.010)
26
.84 (.033)
.404 (.0159)
.79 (.031)
2—60
2.54 (.100)
.25 (.010)
24
.84 (.033)
.511 (.0201)
.94 (.037)
2—45
3.18 (.125)
.51 (.020)
24
.84 (.033)
.511 (.0201)
.94 (.037)
2—35
3.81 (.150)
.51 (.020)
24
.84 (.033)
.511 (.0201)
94 (.037)
2—30
5.08 (.200)
.51 (.020)
24
.84 (.033)
.511 (.0201)
94 (.037)
2—22
Tolerance on pitch: ± .25mm (±.010), non-cumulative
Nomex, Teflon and Kapton are trademarks of E. I. DuPont de Nemours.
Mid-Pin Jumper Thickness (.039), (.049),
(.050), (.075), (.125), (.150), & (.200)
.254 (.010)
Nomex
.254 (.010)
Kapton
.406 (.016)
Teflon
.254 (.010)
Polyester
3.17
± .76
(.125
± .030
E
Pin Dia.
± 025
(
± .0010)
B
± 1.57
(
± .062)
No Nicks
D
(max.)
1
2
1
2
&
Jumper
Thickness
Between
Points
C
(Min.)
A
Tyco Product Specification and Customer Drawing: 1474339
TECHNICAL DOCUMENTS
Technical Support Center
Phone: 1-800-522-6752
Internet: www.amp.com