Average Supply Current from V
DD
(T
A
= 0 to +70°C, V
DD
= V
DDQ
= 3.3 ±0.3 V, V
SS
= V
SSQ
= 0 V, unless otherwise noted)
Symbol
Parameter
Test Conditions
Rating (Max)
Unit
-6
-7
-8
-10
I
CC1S
I
CC1D
I
CC2H
I
CC2L
I
CC3H
I
CC3L
I
CC4
Operating Current, Single Bank
t
RC
= min, t
CLK
= min, BL = 1, CL = 3
t
RC
= min, t
CLK
= min, BL = 1, CL = 3
both banks idle, t
CLK
= min, CKE = H
both banks idle, t
CLK
= min, CKE = L
both banks active, t
CLK
= min, CKE = H
both banks active, t
CLK
= min, CKE = L
t
CLK
= min, BL = 4, CL = 3, both banks
active
120
110
100
90
mA
Operating Current, Dual Bank
170
150
140
120
mA
Standby Current, CKE = H
20
20
20
20
mA
Standby Current, CKE = L
2
2
2
2
mA
Active Standby Current, CKE = H
35
35
35
35
mA
Active Standby Current, CKE = L
4
4
4
4
mA
Burst Current
180
170
160
140
mA
I
CC5
I
CC6
Auto-Refresh Current
t
RC
= min, t
CLK
= min
CKE < 0.2 V
110
100
90
80
mA
Self-Refresh Current
1
1
1
1
mA
Low Power
500
500
500
500
μA
AC Characteristics (T
A
= 0 to +70°C, V
DD
= V
DDQ
= 3.3 ±0.3 V, V
SS
= V
SSQ
= 0 V, unless otherwise noted)
[1]
Symbol
Parameter
-6
-7
-8
-10
Unit
Min
Max
Min
Max
Min
Max
Min
Max
t
CLK
CLK Cycle Time
CL=2
-
9
10
13
ns
CL=3
6
7
8
10
ns
t
CH
t
CL
t
T
t
IS
t
IH
t
RC
t
RCD
t
RAS
t
RP
t
CCD
t
RRD
t
RSC
t
RDL
t
REF
CLK High Pulse Width
2.5
3
3
3.5
ns
CLK Low Pulse Width
2.5
3
3
3.5
ns
Transition Time of CLK
1
10
1
10
1
10
1
10
ns
Input Setup Time (all inputs)
2
2.5
2.5
2.5
ns
Input Hold Time (all inputs)
1
1
1
1
ns
Row Cycle Time
60
63
72
90
ns
Row to Column Delay
18
21
24
30
ns
Row Active Time
42
100k
42
100k
48
100k
60
100k
ns
Row Precharge Time
18
21
24
30
ns
Column Address to Column Adress Delay
1
1
1
1
CLK
Act to Act Delay Time
2
2
2
2
CLK
Mode Register Set Cycle Time
1
1
1
1
CLK
Last Data-In to Row Precharge Delay
1
1
1
1
CLK
Refresh Interval Time
65.6
65.6
65.6
65.6
ms
1. Input Pulse Levels: 0.4 V to 2.4 V with t
r
/t
f
= +1/+1 ns. Input Timing Measurement Level: 1.4 V.
1.4
CLK
Signal
1.4
Any AC timing is
referenced to the
input signal crossing
相關(guān)PDF資料
PDF描述
GLT5160L16 16M (2-Bank x 524288-Word x 16-Bit) Synchronous DRAM
GLT5160L16-10FJ 16M (2-Bank x 524288-Word x 16-Bit) Synchronous DRAM
GLT5640AL16 4M X 16 CMOS Synchronous Dynamic RAM
GLT5640AL16-10TC 4M X 16 CMOS Synchronous Dynamic RAM
GLT5640AL16-5.5TC 4M X 16 CMOS Synchronous Dynamic RAM
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
GLT52 功能描述:線性和開關(guān)式電源 50W Three channel 5V/12V/-12V RoHS:否 制造商:TDK-Lambda 產(chǎn)品:Switching Supplies 開放式框架/封閉式:Enclosed 輸出功率額定值:800 W 輸入電壓:85 VAC to 265 VAC 輸出端數(shù)量:1 輸出電壓(通道 1):20 V 輸出電流(通道 1):40 A 商用/醫(yī)用: 輸出電壓(通道 2): 輸出電流(通道 2): 安裝風(fēng)格:Rack 長度: 寬度: 高度:
GLT52-M 功能描述:線性和開關(guān)式電源 50W Three channel 5V/12V/-12V Medical RoHS:否 制造商:TDK-Lambda 產(chǎn)品:Switching Supplies 開放式框架/封閉式:Enclosed 輸出功率額定值:800 W 輸入電壓:85 VAC to 265 VAC 輸出端數(shù)量:1 輸出電壓(通道 1):20 V 輸出電流(通道 1):40 A 商用/醫(yī)用: 輸出電壓(通道 2): 輸出電流(通道 2): 安裝風(fēng)格:Rack 長度: 寬度: 高度:
GLT53 功能描述:線性和開關(guān)式電源 50W Three channel 5V/15V/-15V RoHS:否 制造商:TDK-Lambda 產(chǎn)品:Switching Supplies 開放式框架/封閉式:Enclosed 輸出功率額定值:800 W 輸入電壓:85 VAC to 265 VAC 輸出端數(shù)量:1 輸出電壓(通道 1):20 V 輸出電流(通道 1):40 A 商用/醫(yī)用: 輸出電壓(通道 2): 輸出電流(通道 2): 安裝風(fēng)格:Rack 長度: 寬度: 高度:
GLT53-M 功能描述:線性和開關(guān)式電源 50W Three channel 5V/15V/-15V Medical RoHS:否 制造商:TDK-Lambda 產(chǎn)品:Switching Supplies 開放式框架/封閉式:Enclosed 輸出功率額定值:800 W 輸入電壓:85 VAC to 265 VAC 輸出端數(shù)量:1 輸出電壓(通道 1):20 V 輸出電流(通道 1):40 A 商用/醫(yī)用: 輸出電壓(通道 2): 輸出電流(通道 2): 安裝風(fēng)格:Rack 長度: 寬度: 高度:
GLT54 功能描述:線性和開關(guān)式電源 50W Three channel 5V/24V/12V RoHS:否 制造商:TDK-Lambda 產(chǎn)品:Switching Supplies 開放式框架/封閉式:Enclosed 輸出功率額定值:800 W 輸入電壓:85 VAC to 265 VAC 輸出端數(shù)量:1 輸出電壓(通道 1):20 V 輸出電流(通道 1):40 A 商用/醫(yī)用: 輸出電壓(通道 2): 輸出電流(通道 2): 安裝風(fēng)格:Rack 長度: 寬度: 高度: