Preset Counter/Timer
H8GN
C-63
C
I
Characteristics
Note:
Refer to the
Life-test Curve
.
Timer function
Accuracy of operating
time and setting error
(including temperature
and voltage effects)
Signal start:
±
0.03%
±
30 ms max.
Power-ON start:
±
0.03%
±
50 ms max.
Insulation resistance
Dielectric strength
100 M
min. (at 500 VDC)
1,500 VAC, 50/60 Hz for 1 min between output terminals and non-current-carrying metal
parts
510 VAC, 50/60 Hz for 1 min between current-carrying terminals (except output terminals)
and non-current-carrying metal parts
1,500 VAC, 50/60 Hz for 1 min between output terminals and current-carrying terminals (ex-
cept output terminals)
500 VAC, 50/60 Hz for 1 min between communications terminals and current-carrying termi-
nals (except output terminals)
1,000 VAC, 50/60 Hz for 1 min between contacts not located next to each other
Square-wave noise by noise simulator;
±
480 V (between power terminals),
±
600 V (between input terminals)
±
8 kV (malfunction),
±
15 kV (destruction)
10 to 55 Hz with 0.35-mm single amplitude each in three directions for 10 min
10 to 55 Hz with 0.75-mm single amplitude each in three directions for 2 h
100 m/s
2
, 3 times each in six directions
300 m/s
2
, 3 times each in six directions
10 million operations
100,000 operations min. (3 A at 250 VAC, resistive load) (See note.)
10
°
C to 55
°
C (with no icing or condensation)
25
°
C to 65
°
C (with no icing or condensation)
25% to 85%
(EMI):
EN61326
Emission Enclosure:
EN55011 Group 1 Class A
(EMS):
EN61326
Immunity ESD:
EN61000-4-2: 4 kV contact discharge (level 2)
8 kV air discharge (level 3)
Immunity RF-interference: EN61000-4-3: 10 V/m (Amplitude-modulated,
80 MHz to 1 GHz) (level 3);
10 V/m (Pulse-modulated,
900 MHz
±
5 MHz) (level 3)
Immunity Conducted
Disturbance:
EN61000-4-6: 3 V (0.15 to 80 MHz) (level 2)
Immunity Burst:
EN61000-4-4: 2 kV power-line (level 3);
1 kV I/O signal-line (level 4);
1 kV communications-line (level 3)
Immunity Surge:
EN61000-4-5: 1 kV between lines
(power and output lines) (level 3);
2 kV between grounds
(power and output lines) (level 3)
UL508, CSA C22.2 No.14
Conforms to EN61010-1/IEC61010-1 (Pollution degree 2/overvoltage category
II
)
Conforms to VDE0106/P 100 (Finger Protection)
Rear section: Gray smoke; Front section: N1.5 (black)
Panel surface: IP66 and NEMA Type 4X (indoors)
Rear case:
IP20
Terminal block: IP20
Approx. 80 g
Noise immunity
Static immunity
Vibration resistance
Malfunction
Destruction
Malfunction
Destruction
Mechanical
Electrical
Operating
Storage
Shock resistance
Life expectancy
Ambient temperature
Ambient humidity
EMC
Approved standards
Case color
Degree of protection
Weight