354
s:
Setting Number. Receiver control setting for which this packet’s values are to be applied. The
following truth table shows the names of each of the values for s that apply to this packet.
s
3
s
2
s
1
s
0
0 1
Setting Name
1 1
1600sps Sync
1 0
0 0
3200sps Data
1 0
0 1
1600sps Data
LBC:
Low Battery Check. If this bit is set, the FLEX decoder will check the status of the LOBAT
port just before leaving this receiver state. (value after reset=0)
CLS:
Control Line Setting. This is the value to be output on the receiver control lines (S0-S7) for
this receiver state. (value after reset=0)
5. Receiver Shut Down Setting Packets
Table 12-15 Receiver Shut Down Setting Packet Bit Assignments
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Byte 3
0
0
0
1
1
0
1
s
Byte 2
SE
0
0
0
LBC
0
0
0
Byte 1
CLS
7
0
CLS
6
0
CLS
5
ST
5
CLS
4
ST
4
CLS
3
ST
3
CLS
2
ST
2
CLS
1
ST
1
CLS
0
ST
0
Byte 0
s:
Setting Number. Receiver control setting for which this packet’s values are to be applied. The
following truth table shows the names of each of the values for s that apply to this packet.
s
Setting Name
0
Shut Down 1
1
Shut Down 2
SE:
Step Enable. The receiver setting is enabled when the bit is set. If a step in the shut down
sequence is disabled, all steps following the disabled step will be ignored. (value after reset=0)
LBC:
Low Battery Check. If this bit is set, the FLEX decoder will check the status of the LOBAT
port just before leaving this receiver state. (value after reset=0)
CLS:
Control Line Setting. This is the value to be output on the receiver control lines (S0-S7) for
this receiver state. (value after reset=0)