3
Specifications HS-1840RH
Absolute Maximum Ratings
Reliability Information
Supply Voltage Between Pins 1 and 27 . . . . . . . . . . . . . . . . . . +40V
+VSUPPLY to Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +20V
-VSUPPLY to Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-20V
VREF to Ground. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +20V
Analog Input Overvoltage
+VS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .+25V (Power On/Off)
-VS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -25V (Power On/Off)
Digital Input Overvoltage
+VEN, +VA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VREF +4V
-VEN, -VA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GND -4V
Continuous Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10mA
Storage Temperature Range . . . . . . . . . . . . . . . . . -65
o
C to +150
o
C
Junction Temperature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +175
o
C
Lead Temperature (Soldering 10s). . . . . . . . . . . . . . . . . . . . +275
o
C
Thermal Resistance . . . . . . . . . . . . . . . . . .
Sidebraze Package . . . . . . . . . . . . . . . . .
Flatpack Package . . . . . . . . . . . . . . . . . .
Total Power Dissipation (Note)
Sidebraze CerDIP Package. . . . . . . . . . . . . . . . . . . . . . . 1600mW
Ceramic Flatpack Package . . . . . . . . . . . . . . . . . . . . . . . 1400mW
ESD Classification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Class 1
θ
JA
θ
JC
83.1
o
C/W
49.1
o
C/W
19.1
C/W
16.5
o
C/W
NOTE: For DIP Derate 20.4mW/
o
C above T
A
= +95
o
C
For Flatpack Derate 18.5mW/
o
C above T
A
= +95
o
C
CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation
of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
Operating Conditions
Operating Supply Voltage (
±
VSUPPLY)
. . . . . . . . . . . . . . . . . . . . ±
15V
Operating Temperature Range. . . . . . . . . . . . . . . . -55
o
C to +125
o
C
VREF (Pin 13) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +5V
Logic Low Level (VAL). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +0.8V
Logic High Level (VAH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +4.0V
TABLE 1. DC ELECTRICAL PERFORMANCE CHARACTERISTICS
Device Guaranteed and 100% Tested. Unless Otherwise Specified: V- = -15V, V+ = +15V, VREF = +5V, VAH = +4.0V, VAL = 0.8V
PARAMETER
SYMBOL
CONDITIONS
GROUP A
SUBGROUPS
TEMPERATURE
LIMITS
UNITS
MIN
MAX
Analog Signal Range
VS
7, 8A, 8B
-55
o
C, +25
o
C,
+125
o
C
-5
+15
V
Input Leakage
Current, Address, or
Enable Pins
IAH
IAL
Measure Inputs Sequentially
Ground All Unused Pins
1, 2, 3
-55
o
C, +25
o
C,
+125
o
C
-1000
1000
nA
Leakage Current Into
the Source Terminal of
an “Off” Switch
+IS(OFF)
VS = +10V, All Unused Inputs
and Output = -10V, VEN = 4V
1
+25
o
C
-10
10
nA
2, 3
+125
o
C,-55
o
C
-100
100
nA
-IS(OFF)
VS = -10V, All Unused Inputs,
Output = +10V, VEN = 4V
1
+25
o
C
-10
10
nA
2, 3
+125
o
C, -55
o
C
-100
100
nA
Leakage Current into
the Source Terminal of
an “Off” Switch With
Power “Off”
+IS(OFF)
Power Off
V+, V-, VREF, A0, A1, A2, A3,A4,
EN = GND, Unused Inputs Tied to
GND, VS = +25V
1
+25
o
C
-50
50
nA
2, 3
+125
o
C, -55
o
C
-100
100
nA
Leakage Current Into
the Source Terminal of
an “Off” Switch With
Overvoltage Applied
+IS(OFF)
Overvoltage
VS = +25V, VD = 0V, VEN = 4V
All Unused Inputs Tied to GND
1, 2, 3
-55
o
C, +25
o
C,
+125
o
C
-1000
1000
nA
-IS(OFF)
Overvoltage
VS = -25V, VD = 0V, VEN = 4V All
Unused Inputs Tied to GND
1, 2, 3
-55
o
C, +25
o
C,
+125
o
C
-1000
1000
nA
Leakage Current Into
the Drain Terminal of
an “Off” Switch
+ID(OFF)
VD = +10V, VEN = 4V All Unused
Inputs = -10V
1
+25
o
C
-10
10
nA
2, 3
+125
o
C, -55
o
C
-100
100
nA
-ID(OFF)
VD = -10V, VEN = 4V All Unused
Inputs = +10V
1
+25
o
C
-10
10
nA
2, 3
+125
o
C, -55
o
C
-100
100
nA
Leakage Current Into
the Drain Terminal of
an “Off” Switch With
Overvoltage Applied
+ID(OFF)
Overvoltage
VS = +25V, Measure VD,
VEN = 4V, All Unused Inputs to
GND
1, 2, 3
-55
o
C, +25
o
C,
+125
o
C
-1000
1000
nA
-ID(OFF)
Overvoltage
VS = -25V, Measure VD,
All Unused Inputs to GND
1, 2, 3
-55
o
C, +25
o
C,
+125
o
C
-1000
1000
nA
Spec Number
518022