Nuclear Event Detector
HSN-1000
2005 Maxwell Technologies
All rights reserved.
01.07.05 Rev 3
F
EATURES
:
Detects ionizing radiation pulses
100% tested/certified detection threshold level
Adjustable circumvention period
100% testable with built-in test
Detection threshold adjustability
Single +5V operation
Radiation hardness guaranteed
Compliant to MIL-PRF-38534 Class H
1
Flat pack (F) or DIP (L) packages
R
ADIATION
H
ARDNESS
C
HARACTERISTICS
:
Dose Rate (operate-through): 1 x 10
12
rad(Si)/sec
Total Dose: 1 x 10
6
rad(Si)
Neutron Fluence: 5 x 10
13
n/cm
2
Approximate Detection Range: 2 x 10
5
- 2 x 10
7
rad(Si)/sec
Maxwell Technologies Specified, Controlled, Tested and
Guaranteed
D
ESCRIPTION
:
Maxwell Technologies’ HSN-1000 radiation-hardened Hybrid
Nuclear Event Detector (NED) senses ionizing radiation pulses
generated by a nuclear event, such as the detonation of a nuclear
weapon, and rapidly switches its output fromthe normal high
state to a low state with a propagation delay time of less than
20ns. The active low Nuclear Event Detection signal (NED) is
used to initiate a wide variety of circumvention functions, thus
preventing upset and burnout of electronic components. The NED
output is also used to initiate both hardware and software recov-
ery. This high-speed, 14-pin hybrid detector is used in electronic
systems as a general-purpose circumvention device to protect
memory, stop data processing, and drive power supply switches
as well as signal clamps.
The HSN-1000 is guaranteed to operate through three critical
environments: ionizing dose rate [10
12
rad(Si)/s], gamma total
dose [10
6
rad(Si)], and neutron fluence [5 x 10
13
n/cm
2
]. In addi-
tion, the device is designed to function throughout the transient
neutron pulse. The hybrids discrete design ensures a controlled
response in these radiation environments as well as immunity to
latchup. Each HSN-1000’s detection level and functionality are
tested in an ionizing dose rate environment. A certificate is pro-
vided with each serialized hybrid, reporting the radiation test
results and guaranteeing its performance. The device is also lot
qualified in the total dose and neutron environments to ensure
performance.
The detection threshold of the HSN-1000 is adjustable within the
range of 2 x 10
5
rad(Si)/s to 2 x 10
7
rad(Si)/s. This detection level
can be preset by Maxwell or adjusted by the user. Less than a
30% variation in detection threshold can be expected over the
entire operating temperature range.
1.
Manufactured for Maxwell Technologies by Teledyne Microelectronic
Technologies to MIL-PRF-38534, Class H, no RHA
Detector
(Pin Diode)
Amplifier
Pulse Timer
LED
4
5
7
6
8
9
14
1
2
V
H
V
L
TAdjust
V
B
BIT
GND
Logic Diagram
C
RC
NED
10 k
相關(guān)PDF資料
PDF描述
HSN-2000 Nuclear Event Detector
HSN-2000F Nuclear Event Detector
HSN-2000L Nuclear Event Detector
HSN-3000 Nuclear Event Detector
HSN-3000F Nuclear Event Detector
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
HSN100F2R0E 制造商:Ohmite Mfg Co 功能描述:Aluminum Housed Wirewound Resistor
HSN100F300E 制造商:Ohmite Mfg Co 功能描述:Res Wirewound 300 Ohm 1% 100W ±30ppm/°C Aluminum Housed AXL Flange Mount
HSN100FR05E 制造商:OHMITE 制造商全稱:Ohmite Mfg. Co. 功能描述:HSN100FR05E Wirewound, Industrial/Commercial Grade
HSN100FR50E 制造商:Ohmite Mfg Co 功能描述:RESISTOR, WIREWOUND, 0.5 OHM, 100W, 5%, Product Range:OHMITE - HSN Series, Resis
HSN100FR88E 制造商:Ohmite Mfg Co 功能描述:WIREWOUND RESISTOR