HUMIREL HPC077VC
HTF3000LF
July 2006
1
TEMPERATURE AND HUMIDITY MODULE HTF3000LF
RoHS Compliant
Based on the rugged HS1101LF humidity sensor, HTF3000LF is a dedicated humidity and temperature
transducer designed for OEM applications where a reliable and accurate measurement is needed. It features a
very small size for easy, cost-effective mechanical mounting. Direct interface with a micro-controller is made
possible with the module’s linear frequency output.
M
AIN FEATURES
One of the smallest humidity / temperature modules on the market.
Compliant with RoHS regulation and most of Lead Free Soldering Process
Stable, proportional frequency output from 0 to 100% RH.
Calibrated within +/- 3% RH @ 55% RH at 3.30 VDC.
High quality thermistor.
Stable characteristics with temperature.
High reliability and long term stability.
H
UMIDITY SENSOR SPECIFIC FEATURES
Instantaneous de-saturation after long periods in saturation phase.
Fast response time.
High resistance to chemicals.
Not affected by water immersion.
Part could be washed with distilled water.
Patented solid polymer structure.
T
EMPERATURE SENSOR SPECIFIC FEATURES
10 k
+/- 1% NTC temperature sensor
Stable
High sensitivity
M
AXIMUM RATINGS
C
HARACTERISTICS
Humidity sensor(
Ta =23°C, Vs=3.3Vdc, R
L
>100K
unless otherwise stated)
Characteristics
Symbol
Min.
Typ.
Max.
Unit.
Relative Humidity accuracy (0 to 100 % RH)
RH
Refer to Chart 2 on page 2
Voltage supply
Vs
3
3.30
16
VdC
Nominal output @ RH = 55 % and 3. 3Vdc
Fout
6560
6600
6640
Hz
Current consumption
(Max at 16Vdc)
Ic
0.18
1
mA
Voltage supply influence (3 to 7 Vdc)
RH
+/-1
% RH
Averaged Sensitivity from 10% to 95% RH
Fout /
RH
-10
- 12
-14
Hz/% RH
Humidity Hysteresis
+/-1
% RH
Long term stability
0.5
% RH/yr
Time constant (40 to 95% RH, 2m/s, @63 %)
τ
10
s
Ratings
Symbol
Value
Unit
Storage Temperature
Tstg
-40 to 105
°C
Storage Humidity Range
RHstg
0 to 100
% RH
Supply Voltage (Peak)
Vs
16
Vdc
Humidity Operating Range
RH
0 to 100
% RH
Temperature Operating Range
Ta
-40 to 85
°C
Chart1