71
JQ RELAYS
VDE
HIGH ELECTRICAL &
MECHANICAL NOISE
IMMUNITY RELAY
mm
inch
20
.787
10
.394
15.6
.614
FEATURES
High electrical noise immunity
High switching capacity in a compact package
High sensitivity: 200 mW (1a), 400 mW (1c)
High surge voltage: 8,000 V between contacts and coil
UL, CSA, VDE, TüV, SEMKO approved
Class B coil insulation type available
SPECIFICATIONS
Contact
Expected electrical life (min. operations)
Type
Coil (at 20
°
C
68
°
F
)
Nominal operating power
Characteristics
Max. operating speed
Initial insulation resistance*
1
Remarks
*
Specifications will vary with foreign standards certification ratings.
*
1
Measurement at same location as "Initial breakdown voltage" section
*
2
Detection current: 10 mA
*
3
Wave is standard shock voltage of
±
1.2
×
50
μ
s according to JEC-212-1981
*
4
Excluding contact bounce time
*
5
Measured conditions
Resistive, nominal voltage applied to the coil.
Contact carrying current: 5 A, at 70
°
C
158°F
Resistive, nominal voltage applied to the coil.
Contact carrying current: 10 A, at 70
°
C
158°F
*
6
Half-wave pulse of sine wave: 11ms; detection time: 10
μ
s
*
7
Half-wave pulse of sine wave: 6ms
*
8
Detection time: 10
μ
s
*
9
Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 24).
*
10
When using relays in a high ambient temperature, consider the pick-up voltage
rise due to the high temperature (a rise of approx. 0.4% V for each 1°C
33.8°F
with 20°C
68°F
as a reference) and use a coil impressed voltage that is within
the maximum allowable voltage range.
Standard type
High capacity type
Arrangement
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Contact material
1 Form A, 1 Form C
100 m
Silver alloy
Rating
(resistive)
Nominal
switching
capacity
1a
5 A 125 V AC
2 A 250 V AC
5 A 30 V DC
5 A 125 V AC
2 A 250 V AC
3 A 30 V AC
2 A 125 V AC
1 A 250 V AC
1 A 30 V DC
625 VA, 150 W
625 VA, 90 W
250 VA, 30 W
250 V AC, 110 V DC (0.3A)
N.O.: 5 A N.C.: 2 A
10 A 125 V AC
5 A 250 V AC
5 A 30 V DC
10 A 125 V AC
5 A 250 V AC
5 A 30 V DC
3 A 125 V AC
2 A 250 V AC
1 A 30 V DC
1,250 VA, 150 W
1,250 V AC, 150 W
500 V AC, 30 W
1c
N.O.
N.C.
Max.
switching
power
1a
1c
N.O.
N.C.
Max. switching voltage
Max. switching current
Expected mechanical life
(at 180 cpm)(min. operations)
N.O.: 10 A N.C.: 3 A
10
7
Switching capacity
5 A 125 V AC
3 A 125 V AC
2 A 250 V AC
5 A 30 V DC
5 A 125 V AC
2 A 250 V AC
3 A 30 V DC
2 A 125 V AC
1 A 250 V AC
1 A 30 V DC
10 A 125 V AC
5 A 250 V AC
5 A 30 V DC
10 A 125 V AC
5 A 250 V AC
5 A 30 V DC
3 A 125 V AC
2 A 250 V AC
1 A 30 V DC
No. of operations
5
×
10
4
2
×
10
5
2
×
10
5
10
5
5
×
10
4
2
×
10
5
10
5
2
×
10
5
2
×
10
5
10
5
5
×
10
4
5
×
10
4
10
5
5
×
10
4
5
×
10
4
10
5
2
×
10
5
2
×
10
5
10
5
Standard type
1a
1c
N.O.
N.C.
High capacity
type
1a
1c
N.O.
N.C.
1a: 200 mW
1c: 400 mW
20 cpm
Min. 1,000 M
at 500 V DC
1a: 1,000 Vrms for 1 min.
1c: 750 Vrms for 1 min.
4,000 Vrms for 1 min.
Initial
breakdown
voltage*
2
Between open contacts
Between contacts and coil
Surge voltage between
contact and coil*
3
Operate time*
4
(at nominal voltage)
Release time*
4
(at nominal voltage)(without diode)
Temperature rise*
5
Functional*
6
Destructive*
7
8,000 V
Approx. 5 ms
Approx. 2 ms
Max. 45
°
C
Min. 294 m/s
2
{30 G}
Min. 980 m/s
2
{100 G}
98 m/s
2
{10 G}, 10 to 55 Hz
at double amplitude of 1.6 mm
117.6 m/s
2
{12 G}, 10 to 55 Hz
at double amplitude of 2.0 mm
–40
°
C to +85
°
C
–40
°
F to +185
°
F
Shock
resistance
Vibration
resistance
Functional*
8
Destructive
Conditions for operation,
transport and storage*
9
(Not freezing and condens-
ing at low temperature)
Unit weight
Ambient
temp.*
10
Humidity
5 to 85% R.H.
Approx. 7 g .
25 oz
Standard type
High capacity type