3
www.fairchildsemi.com
K
Absolute Maximum Ratings
(Note 1)
Note 1:
The “Absolute Maximum Ratings” are those values beyond which the safety of the device cannot be guaranteed. The device should not be operated at these limits. The
parametric values defined in the Electrical Characteristics tables are not guaranteed at the absolute maximum ratings. The “Recommended Operating Conditions” table will define
the conditions for actual device operation.
Electrical Characteristics
(V
CC
= 15V, V
EE
= 15V, T
A
= 25 C, unless otherwise specified)
Note 2:
0 T
A
70 C.
Note 3:
The response time specified is for a 100mV input step with 5mV over drive.
Parameter
Symbol
Value
Unit
Total Supply Voltage
V
CC
|V
EE
|
V
O
- V
EE
V
EE
V
I(DIFF)
V
I
–
36
V
Output to Negative Supply Voltage KA311
40
V
Ground to Negative voltage
30
V
Differential Input Voltage
30
V
Input Voltage
15
V
Output Short Circuit Duration
10
sec.
Power Dissipation
P
D
T
OPR
T
STG
500
mW
Operating Temperature Range
0 70
C
Storage Temperature Range
65 150
C
Parameter
Symbol
Conditions
Min
Typ
Max
Unit
Input Offset Voltage
V
IO
RS 50k
–
1.0
7.5
mV
(Note 2)
–
–
10.0
Input Offset Current
I
IO
–
6.0
50.0
nA
(Note 2)
–
–
70.0
Input Bias Current
I
BIAS
–
100
250
nA
(Note 2)
–
–
300
Voltage Gain
G
V
40.0
200
–
V/mV
Response Time
t
RES
(Note 3)
–
200
–
ns
Saturation Voltage
V
SAT
I
O
= 50mA, V
I
10mV
–
0.75
1.5
V
V
CC
4.5V, V
EE
= 0V, I
O
= 8mA, V
I
10mV
(Note 2)
–
0.23
0.4
Strobe “ON” Current
I
STR(ON)
–
3.0
–
mA
Output Leakage Current
I
SINK
I
STR
= 3mA, V
I
10mV, V
O
= 15V, V
CC
= 15V
–
0.2
50.0
nA
Input Voltage Range
V
I(R)
(Note 2)
14.5 to 13.0
14.7 to 13.8
–
V
Positive Supply Current
I
CC
–
3.0
7.5
mA
Negative Supply Current
I
EE
–
2.2
5.0
mA
Strobe Current
I
STR
–
3.0
–
mA