LA17000M
No. 6522-21/54
Continued from preceding page.
No.
Control block/Data
Description
Related data
This data sets the general-purpose counter input pin (HCTR).
General-purpose counter measurement start data
CTE = 1: Count start
= 0: Count reset
This data determines the measurement time (frequency mode) and number of
periods (period mode) for the general-purpose counter.
CTP = 0: When a count reset is executed (CTE = 0), the general-purpose
counter input is pulled down.
= 1: When a count reset is executed (CTE = 0), the general-purpose
counter input is not pulled down, and the wait time is reduced.
However, immediately after CTP = 1 is set, the start of the count
must wait until the general purpose counter input pin is biased.
The input sensitivity is reduced when CTC = 1. (Sensitivity: 10 to 30 mVrms)
I/O port control data
This data specifies whether an I/O port is an input port or an output port.
“data”= 0: Input port
= 1: Output port
I/O-1 to I/0-2
* During a power-on reset, I/O-0 and I/O-2 become input ports.
STSD SW becomes an output port.
This data determines the status of the SEEK SW pin.
“data” = 0: 2.5[V] output
SEEK SW
* This pin is open and the midpoint bias is output by an external circuit.
“data” = 1: 0[V] or 5[V] output
* Determined by the OUT0 data.
AM/FM SD, FM-ST IND output dual-purpose pin
SDST SW
“data” = 0: Fixed
= 1: Prohibited
Output port data
This data determines the output on output ports O-0 through O-3.
“data” = 1: Open or Hi
OUT0 to OUT2
= 0: Low
* Invalid if specified as an input port or unlocked output.
This data converts the general-purpose counter pin to an input port.
HCTR = 0: Prohibited
= 1: HCTR (general-purpose counter)
Continued on next page.
CTS1
Measurement time
Measurement mode
1
HCTR
Frequency
0
—
Not measured
HCTR
(6)
Frequency measurement mode
Period
GT1
GT0
Measurement
Wait time (ms)
measurement
time (ms)
CTP = 0
CTP = 1
mode
0
4
3 to 4
1 to 2
1 period
0
1
8
3 to 4
1 to 2
1 period
1
0
32
7 to 8
1 to 2
2 periods
1
64
7 to 8
1 to 2
2 periods
OUT0 to OUT3
ULD
I/O-0 to I/O-3
ULD
I/O-0 to I/O-3
ULD
I/O-0 to I/O-3
ULD
CTS1
(7)
(8)
(9)
(10)
(11)
General-purpose counter
control data
CTS0, CTS1
CTE
GT0, GT1
CTP
CTC
General-purpose counter
input control data
HCTR