2.3 W 2-Channel AF Power Amplifier for Radio
Cassette Players
Features
.
Built-in 2 channels enabling use in stereo and bridge
amplifier (BTL) applications.
.
High-output:
2.3 W typ./channel, VCC =9 V, RL =4
4.7 W typ./bridge amplifier, VCC =9 V, RL =8
.
Low switching distortion at high frequencies.
.
Minimum number of external parts required: 9 pcs. min.
(Stereo/bridge).
.
Small shock noise at the time of power supply ON/OFF due
to built-in muting circuit.
.
Good ripple rejection due to built-in ripple filter.
.
Soft tone at the time of output saturation.
.
Good channel separation.
.
Voltage gain fixed at 45 dB (Bridge: 51 dB).
Variable voltage gain available with external resistor added.
Package Dimensions
unit : mm
3022A-DIP12F
[LA4183]
1
6
12
7
3.46
3.5
4.26max
0.51min
19.4
0.81
2.54
5.12
1.3
3.6
0.5
0.4
7.62
6.45
SANYO : DIP12F
Note:
In general applications, heat generated in the DIP 12-pin
package can be radiated through the Cu-foiled area of the
printed circuit board, but since power dissipation Pd may be
increased depending on the supply voltage and load conditions,
it is recommended to use a fin additionally.
Specifications
Maximum Ratings at Ta = 25°C
Parameter
Symbol
Conditions
Ratings
Unit
Maximum supply
voltage
VCC max
With signal
11
V
Quiescent
15
V
Allowable power
dissipation
Pd max
With
printed
circuit board
(Refer to Pd –
Ta
character-
istics)
4W
Operating
temperature
Topr
–20 to +75
°C
Storage
temperature
Tstg
–55 to +150
°C
Operating Conditions at Ta = 25°C
Parameter
Symbol
Conditions
Ratings
Unit
Recommended
supply voltage
VCC
9.0
V
Load resistance
RL
Stereo
4.0 to 8.0
Bridge
8.0
Ordering number: EN887B
Monolithic Linear IC
LA4183
Any and all SANYO products described or contained herein do not have specifications that can handle
applications that require extremely high levels of reliability, such as life-support systems, aircraft’s
control systems, or other applications whose failure can be reasonably expected to result in serious
physical and/or material damage. Consult with your SANYO representative nearest you before using
any SANYO products described or contained herein in such applications.
SANYO assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or other
parameters) listed in products specifications of any and all SANYO products described or contained
herein.
SANYO Electric Co.,Ltd. Semiconductor Company
TOKYO OFFICE Tokyo Bldg., 1-10, 1 Chome, Ueno, Taito-ku, TOKYO, 110-8534 JAPAN
53096HA(II)/O0207TA/2022KI,TS,ID No.887-1/12