![](http://datasheet.mmic.net.cn/190000/LBA110S_datasheet_14924084/LBA110S_1.png)
1A/1B
mADC
5.0
2.0
mADC
0.1
1.8
mADC
10
30
VDC
1.1
1.4
mADC
50
VDC
10
400
250
mA
150
200
mA
110
150
mA
380
W
24
13
GW
0.5
5000
GW
0.5
5000
200
0.17
Max
0.02
5.0
1.0
0.2
3750
1.2
600
Photomos
/ 1A/1B
* I
F = 10mA
Model Number
Parameters
Input Characteristics
LED Forward Current - Turn on
LED Forward Current - Turn off
Recommended Forward Current
LED Forward Voltage
Sym.
Test Conditions
Units
LBA110
LBA126
1A/1B
Maximum Input Ratings
LED Forward Current
LED Reverse Voltage Withstand
Output Characteristics
Switching Voltage
Switching Current
Current Limit: N.O. Channel Only
On Resistance
Off State Resistance: N.O. Channel
Off State Resistance: N.C. Channel
Off State Leakage: N.O. Channel
Off State Leakage: N.C. Channel
Turn On Time
Turn Off Time
Thermal Offset Voltage
General Characteristics
Dielectric Strength - Input to Output
Capacitance - Input to Output
Power Dissipation
I
Fon
I
Foff
I
F
V
F
I
F
V
R
V
L
I
L
I
Lmt
R
on
R
off
I
off
I
off
T
on
T
off
P
Diss
R
off
I
off
I
off
IL = 100mA, t = 10ms
IL = 0.2mA, VL = (Note 1)
I
F = 20mA
I
R = 10mA
I
L = 50mA
Each Channel
Both Ch.'s Simultaneously
I
F = 5mA, t = 5ms
I
F = 0mA, VL = 100V
I
F = 5mA, VL = 100V
I
F = 5mA/0mA, IL = 50mA
I
F = 0mA, VL = 100V
I
F = 0mA, VL = Max
I
F = 5mA, VL = 100V
I
F = 5mA, VL = Max
I
F = 5mA, IL = 50mA
I
F = 5mA, IL = 50mA
I
F = 5mA
t = 60sec
V PEAK
nA
mA
ms
mV
VRMS
pF
mW
Max
Min
Typ
Max
Min
Typ
Min
Typ
Max
Typ
Max
Typ
Min
Typ
Max
mA
Typ
Notes:
1: VL for LED Forward Current - Turn Off is 50 Volts less than "Switching
Voltage Max".
2: Specifications subject to change without notice.
Schematic Top View:
Mold mark on top of relay indicates Pin #1
Package Drawings on Page 3
Solid State Relays
1
Page 1 of 3
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506