No. 6298-3/5
LC99452
Modes of Operation
The LC99452 has been especially designed for high-resolution low cost digital photography in color full 1600
×
1280
resolution and real-time monitoring (preview) mode in color at reduced resolution. Two main modes of operation are
possible:
Still picture mode (mode-1)
In still picture mode, a 1600 (H)
×
1280 (V) progressive scan image can be read out. A 'single shot' mechanical shutter is
required to obtain a 100% smear free image.
Preview mode (mode-2)
In preview mode, image with a reduced vertical resolution by on-chip data compression can be obtained. Progressive
scan images (mode-2), e.g. 120, 240 or 288 lines at up to 40 images/s, suitable for LCD displays can be selected by the
timing generator.
Clock Voltage Conditions
Parameter
Symbol
Ratings
Unit
Cap per phase
min
typ
max
Input resistanImage area pulses
Phi 1 to 4
Pulse amplitude
V
PIF
V
LIF
V
PSL
V
LSL
V
PH
V
LH 13
V
LH 24
V
PR
V
HR
V
PSUB
11
12
13
V
5.5 nF
Low level
0
V
Storage area pulses
Phi-S 1 to 4
Pulse amplitude
11
12
13
V
1.5 nF
Low level
0
V
Horizontal register pulses
Phi-H 1 to 4
Pulse amplitude
4.5
5.0
5.25
V
60 pF
Low level C1,C3
0
V
Low level C2,C4
2.5
3
3.5
V
Reset gate pulses
Phi-R
Pulse amplitude
4.5
5
5.25
V
15 pF
*
1
High level
21
22
23
V
Charge reset pulse on Nsub
4.5
5
5.5
V
Note:
*
1. DC setting depends on RG clock-swing.
DC Electrical Characteristics
Parameter
Symbol
Ratings
Unit
I (mA)
min
typ
max
N-sub bias
V
LSUB
V
PW
V
DD
V
SS
V
OG
V
RD
20
24
28
V
2
*
1
P-well bias
6
7
9
V
2
Output circuit power supply
19
20
21
V
5.5
*
2
0
0
0
V
1
*
2
OG bias
3.5
4.0
4.5
V
*
3
Reset drain bias
19
20
21
V
Notes: 1. V
is set for optimal anti-blooming operation.
2. with RL = 3.3 k
, V
should be adjusted at the same voltage as V
RD
.