    8/26
    Thermal Considerations
    If a converter is located in free, quasi-stationary air (con-
    vection cooling) at the indicated maximum ambient tem-
    perature
    TA max (see table: Temperature specifications) and
    is operated at its nominal input voltage and output power,
    the temperature measured at the
    Measuring point of case
    temperature TC (see: Mechanical Data) will approach the
    indicated value
    TC max after the warm-up phase. However,
    the relationship between
    TA and TC depends heavily on the
    conditions of operation and integration into a system. The
    thermal conditions are influenced by input voltage, output
    current, airflow and temperature of surrounding compo-
    nents and surfaces.
    TA max is therefore, contrary to TC max,
    an indicative value only.
    Caution: The installer must ensure that under all operat-
    ing conditions
    TC remains within the limits stated in the
    table:
    Temperature specifications.
    Notes: Sufficient forced cooling or an additional heat sink
    allows
    TA to be higher than 71
    °C (e.g. 85°C) if T
    C max is not
    exceeded.
    For -7 or -9 units at an ambient temperature
    TA of 85°C with
    only convection cooling, the maximum permissible current
    for each output is approx. 40% of its nominal value as per
    figure.
    0
    0.1
    0.2
    0.3
    0.4
    0.5
    0.6
    0.7
    0.8
    50
    60
    70
    80
    90
    100
    Io/Io nom
    TA [°C]
    0.9
    1.0
    Forced cooling
    05089
    TA min
    TC max
    Convection cooling
    Fig. 7
    Output current derating versus temperature for –7 and –9.
    Thermal Protection
    A temperature sensor generates an internal inhibit signal
    which disables the outputs if the case temperature exceeds
    TC max. The outputs are automatically re-enabled if the tem-
    perature drops below this limit.
    It is recommended that continuous operation under simul-
    taneous extreme worst case conditions of the following
    three parameters be avoided: Minimum input voltage,
    maximum output power and maximum temperature.
    Output Protection
    Each output is protected against overvoltage which could
    occur due to a failure of the control circuit by means of a
    voltage suppressor diode which, under worst case condi-
    tions, may become a short circuit. The suppressor diodes
    are not designed to withstand externally applied over-
    voltages. Overload at any of the two outputs will cause a
    shut-down of both outputs. A red LED indicates the over-
    load condition.
    Uo1d
    t d
    Ur
    t
    Uo2d
    <10
    s
    <10
    s
    Uo1
    Uo2
    Io1/Io1 nom
    0
    0.5
    1
    Io2/Io2 nom
    05072
    Fig. 8
    Control deviation of uo1/2 d vs. dynamic load change.
    Output Voltage Regulation of Single or Double Output
    Modules with Outputs1 and 2 Connected in Series
    Uo
    Uo nom
    0.98
    0.5
    0
    0.5
    1.0
    Io1
    IoL
    Io
    Io nom
    05068
    Fig. 9
    Uo1 versus Io1 (typ.) of single output units
    Parallel or Series Connection of Units
    Single or double output units with equal nominal output volt-
    age can be connected in parallel without any precautions
    using option T.
    With option T (current sharing), all units share the current
    approximately equally.
    Single output units and/or main and second outputs of dou-
    ble output units can be connected in series with any other
    (similar) output.
    Note:
    – Parallel connection of double output units should always
    include both, main and second output to maintain good
    regulation of both outputs.
    – Not more than 5 units should be connected in parallel.
    – Series connection of second outputs without involving
    their main outputs should be avoided as regulation may
    be poor.
    – The maximum output current is limited by the output with
    the lowest current limitation if several outputs are con-
    nected in series.
    相關(guān)PDF資料
    PDF描述
    LK1001-9PD9 1-OUTPUT 150 W AC-DC REG PWR SUPPLY MODULE
    LK1001-9RD5B2 1-OUTPUT 150 W AC-DC REG PWR SUPPLY MODULE
    LK1001-9RD7TB1 1-OUTPUT 150 W AC-DC REG PWR SUPPLY MODULE
    LK1301-7D8 1-OUTPUT 150 W AC-DC REG PWR SUPPLY MODULE
    LK1301-7EB2 1-OUTPUT 150 W AC-DC REG PWR SUPPLY MODULE
    相關(guān)代理商/技術(shù)參數(shù)
    參數(shù)描述
    LK100-24P 制造商:未知廠家 制造商全稱:未知廠家 功能描述:Optoelectronic
    LK100-28P 制造商:未知廠家 制造商全稱:未知廠家 功能描述:Optoelectronic
    LK10051R0K-T 功能描述:固定電感器 INDCTR STD MULTILYR 0402 1uH 10% RoHS:否 制造商:AVX 電感:10 uH 容差:20 % 最大直流電流:1 A 最大直流電阻:0.075 Ohms 工作溫度范圍:- 40 C to + 85 C 自諧振頻率:38 MHz Q 最小值:40 尺寸:4.45 mm W x 6.6 mm L x 2.92 mm H 屏蔽:Shielded 端接類型:SMD/SMT 封裝 / 箱體:6.6 mm x 4.45 mm
    LK10051R0K-T 制造商:TAIYO YUDEN 功能描述:Inductor Series:LF LK
    LK10051R0K-TV 功能描述:FIXED IND 1UH 20MA 640 MOHM SMD 制造商:taiyo yuden 系列:LK 包裝:剪切帶(CT) 零件狀態(tài):在售 類型:多層 材料 - 磁芯:- 電感:1μH 容差:±10% 額定電流:20mA 屏蔽:無屏蔽 DC 電阻(DCR):640 毫歐 不同頻率時的 Q 值:20 @ 10MHz 頻率 - 自諧振:60MHz 等級:AEC-Q200 工作溫度:-40°C ~ 85°C 頻率 - 測試:10MHz 安裝類型:表面貼裝 封裝/外殼:0402(1005 公制) 供應(yīng)商器件封裝:0402(1005 公制) 大小/尺寸:0.039" 長 x 0.020" 寬(1.00mm x 0.50mm) 高度 - 安裝(最大值):0.022"(0.55mm) 標(biāo)準(zhǔn)包裝:1