Table 14: Pin allocation
Electrical determination
A…LM 1000
C...LMZ 1000
A…LM 2000
C...LMZ 2000
A…LM 3000
C...LMZ 3000
Pin
Ident
Pin
Ident
Pin
Ident
Pin
Ident
Pin
Ident
Pin
Ident
Inhibit control input
2
i
2
i
2
i
2
i
2
i
2
i
Safe Data or ACFAIL
5
D or V
5
D or V
5
D or V
5
D or V
5
D or V
5
D or V
Output voltage (positive)
8
Vo1+
8
Vo1+
8
Vo3+
8
Vo3+
Output voltage (negative)
11
Vo1–
11
Vo1–
11
Vo3–
11
Vo3–
Control input + 1
14
R
14
R
Control input –
17
G
17
G
Output voltage (positive)
14
Vo2+
14
Vo2+
14
Vo2+
14
Vo2+
Output voltage (negative)
17
Vo2–
17
Vo2–
17
Vo2–
17
Vo2–
Output voltage (positive)
20
Vo1+
20
Vo1+
20
Vo1+
20
Vo1+
20
Vo1+
20
Vo1+
Output voltage (negative)
23
Vo1–
23
Vo1–
23
Vo1–
23
Vo1–
23
Vo1–
23
Vo1–
Protective earthing 2
26
DC input voltage 3
29
Vi+
29
Vi+
29
Vi+
29
Vi+
29
Vi+
29
Vi+
DC input voltage
32
Vi–
32
Vi–
32
Vi–
32
Vi–
32
Vi–
32
Vi–
AC input voltage 4
29
N
29
N
29
N
29
N
29
N
29
N
AC input voltage
32
P
32
P
32
P
32
P
32
P
32
P
1 This function is not simultaneously available with option P
3 AM, BM, CM, DM, EM, FM and CMZ, DMZ types
2 Leading pin (pregrounding)
4 LM and LMZ types
Safety and Installation Instructions
Connector Pin Allocation
The connector pin allocation table defines the electrical
potentials and the physical pin positions on the H11 con-
nector. Pin no. 26, the protective earth pin present on all
AM…LM (class I equipment) DC-DC converters is leading,
ensuring that it makes contact with the female connector
first.
32 29 26 23 20 17 14 11 85 2
10015
Fig. 17
View of male H11 connector.
Installation Instructions
The M series DC-DC converters are components, intended
exclusively for inclusion within other equipment by an in-
dustrial assembly operation or by professional installers. In-
stallation must strictly follow the national safety regulations
in compliance with the enclosure, mounting, creepage,
clearance, casualty, markings and segregation require-
ments of the end-use application. See also:
Technical Infor-
mation: Installation and Application.
Connection to the system shall be made via the female con-
nector H11 (see
Accessories). Other installation methods
may not meet the safety requirements.
AM...LM DC-DC converters (class I equipment) are pro-
vided with pin no. 26 (
), which is reliably connected with
their case. For safety reasons it is essential to connect this
pin with the protective earth of the supply system if required
in:
Safety of operator accessible output circuit .
An input fuse is built-in in the connection from pin no. 32
(Vi– or P ) of the unit. Since this fuse is designed to protect
the unit in case of an overcurrent and does not necessarily
cover all customer needs, an external fuse suitable for the
application and in compliance with the local requirements
might be necessary in the wiring to one or both input pins
(no. 29 and/or no. 32).
Important: Whenever the inhibit function is not in use,
pin 2 (i) should be connected to pin 23 (Vo1–) to enable
the output(s).
Do not open the modules, or guarantee will be invali-
dated.
Make sure that there is sufficient air flow possible for con-
vection cooling. This should be verified by measuring the
case temperature when the unit is installed and operated in
the end-use application. The maximum specified case tem-
perature
TC max shall not be exceeded. See also: Thermal
Considerations.
If the end-product is to be UL certified, the temperature of
the main isolation transformer should be evaluated as part
of the end-product investigation.
Protection Degree
Condition: Female connector fitted to the unit.
IP 40: All units, except those with options P, A or K, and
except those with option D or V with potentiometer.
IP 30: All units fitted with options A or K, except those with
option P, and except those with option D or V with
potentiometer.
IP 20: All units fitted with option P, or with option D or V with
potentiometer.
Cleaning Agents
In order to avoid possible damage, any penetration of liq-
uids (e.g. cleaning fluids) is to be prevented, since the
power supplies are not hermetically sealed.
相關(guān)PDF資料
PDF描述
LM1301-7RD3 1-OUTPUT 50 W AC-DC REG PWR SUPPLY MODULE
LM1301-7RV3AHF 1-OUTPUT 50 W AC-DC REG PWR SUPPLY MODULE
LM1301-9EPD3AHF 1-OUTPUT 50 W AC-DC REG PWR SUPPLY MODULE
LM1301-9EPD5 1-OUTPUT 50 W AC-DC REG PWR SUPPLY MODULE
LM1301-9EPD6 1-OUTPUT 50 W AC-DC REG PWR SUPPLY MODULE
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
LM1301-9R 制造商:Power-One 功能描述:AC/DC Power Supply Single-OUT 12V 4A 50W 11-Pin 制造商:Power-One 功能描述:LM Series 50W Single Output 12V AC/DC Power Supply
LM13080N/A+ 制造商:未知廠家 制造商全稱:未知廠家 功能描述:Voltage-Feedback Operational Amplifier
LM13080N/B+ 制造商:未知廠家 制造商全稱:未知廠家 功能描述:Voltage-Feedback Operational Amplifier
LM130A-12C318 制造商:未知廠家 制造商全稱:未知廠家 功能描述:Sunlight Readable 12.1 LCD Module
LM130SS1T611 制造商:SHARP 制造商全稱:Sharp Electrionic Components 功能描述:Color STN-LCD Module