Revision Ver 1.0 October 14, 1998 Page
18/25
LM151X2
Liquid Crystal Display
Product Specification
-2. The Supplier shall screen all of the products in the lot and repair or replace the defective products
within a reasonable time period at the Customer’s facility.
-3. The Customer shall screen the entire lot for the good LCMs at the expense of the Supplier to be
separately agreed upon. The rejected products shall be returned to the place designated by the Supplier.
8. Inspection Specifications
a) General conditions
i) The environment conditions
- Ambient temperature : 20~25
- Humidity : 65 5%RH
- Ambient illumination : Single 20W fluorescent lamp non-directive (About 300 to 700 Lux)
ii) Viewing distance
The distance between the LCM and the eyes of the inspector shall be at least 35cm.
III) Inspection zone for external inspection
External inspection should be performed from front side(Display area)
b) External Inspection Standards
Inspection items
Dent
Scratches
Inspection Standards
Remark
Dot shape
Line shape
Dot shape
Line shape
D 0.5, N 8
0.01 W 0.2, 5 L 20, N 4
0.2 D 0.5, N 5
0.05 W 0.1, 0.3 L 3.0, N 5
On the polarizer
On the polarizer
Operating
Operating
Stain inclusion
W : Width(mm)
L : Length(mm)
D : Average diameter(mm)
Note) Those extraneous substances which can be wiped out easily are acceptable.
c) Display-on Inspection(Visual inspection)
i) Dot Defect
- Bright Dot Defects : When the LCM is turned on, dots(sub-pixels) which appear bright in the display
area at Black(Dark) Mode are bright dot defects.
R, G or B 1 dot
: 6 Max.
R, G or B join 2 dots : 1 Max.
R, G or B join 3 dots : 0 max.
Minimum Distance between defects : D 10mm
Total amount of Bright dot defects : 6 Max.
- Black Dot defects : When the LCM is turned on, dots(sub-pixels) which appear black in the display
area at White(Bright) Mode are black dot defects.
1 dot : 6 Max.
Join 2 dots : 1 Max.
Join 3 dots : 0 max.
Minimum Distance between defects : D 10mm
Total amount of Black dot defects : 6 Max.
- Total amount of Dot Defect(Bright and Black Dot) : 10 Max. (Combination)
ii) Line Defect
All line defects such as vertical, horizontal or cross line defect are not allowed.
Note 1) Dot Defect : Defected area > 1/2 dot
2) 1 Dot : Defect dot is isolated, not attached to other defect dot.
3) 3 Join N Dot : N dots are consecutive. (N means the number of defect dots)
9. Other
If any problems arise with the LCM supplied by LGE, the Customer and Supplier will cooperate and make
efforts to solve it with mutual confidence and respect.
Alpha Point Ltd.
P.O. Box 41
00751 Helsinki, Finland
http://www.
alpha.fi
Tel.: +
358-9-34 64 34 1
Fax: +
358-9-34 64 34 2