SLVS075H APRIL 1989 REVISED FEBRUARY 2005
3
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Reverse current, I
R
Forward current, I
F
Package thermal impedance,
θ
JA
(see Notes 1 and 2): D package
30 mA
10 mA
97
°
C/W
140
°
C/W
95
°
C/W
149
°
C/W
150
°
C
260
°
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
LP package
. . . . . . . . . . . . . . . . . . . . . . . . . .
PS package
. . . . . . . . . . . . . . . . . . . . . . . . . . .
PW package
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating virtual junction temperature, T
J
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds
Storage temperature range, T
stg
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES:
1. Maximum power dissipation is a function of TJ(max)
,
θ
JA, and TA. The maximum allowable power dissipation at any allowable ambient
temperature is PD = (TJ(max) TA)/
θ
JA. Operation at the absolute maximum TJ of 150
°
C can affect reliability.
2. The package thermal impedance is calculated in accordance with JESD 51-7.
65
°
C to 150
°
C
recommended operating conditions
MIN
MAX
UNIT
IZ
Reference current
0.01
20
mA
TA
Operating free-air temperature range
LM285-1.2
LM385-1.2, LM385B-1.2
40
85
70
°
C
0