LM107, LM207, LM307
HIGH-PERFORMANCE OPERATIONAL AMPLIFIERS
SLOS060 – D962, DECEMBER 1970 – REVISED SEPTEMBER 1990
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
3
electrical characteristics at specified free-air temperature (see Note 5)
PARAMETER
TEST CONDITIONS
LM107, LM207
MIN
TYP
LM307
TYP
UNIT
MAX
MIN
MAX
7.5
10
VIO
Input offset voltage
VO= 0
VO = 0
25
°
C
Full range
0.6
2
3
2
mV
α
VIO
Average temperature coefficient
of input offset voltage
VO = 0
Full range
3
15
6
30
μ
V/
°
C
IIO
Input offset current
VO= 0
VO = 0
25
°
C
Full range
1.5
10
20
0.2
0.1
3
50
70
nA
TA = –55
°
C to 25
°
C
TA = 25
°
C to MAX
TA = 0
°
C to 25
°
C
TA = 25
°
C to 70
°
C
0.02
0.01
α
IIO
Average temperature coefficient
of input offset current
nA/
°
C
0.002
0.001
0.6
0.3
250
300
IIB
Input bias current
25
°
C
Full range
30
75
100
70
nA
VICR
Common-mode input voltage
range
See Note 6
Full range
±
15
±
12
V
VCC
±
=
±
15 V,
RL = 10 k
VCC
±
=
±
15 V,
RL = 2 k
VCC
±
=
±
15 V,
VO =
±
10 V,
RL = 2 k
25
°
C
Full range
25
°
C
Full range
25
°
C
Full range
24
24
20
20
50
25
28
24
24
20
20
25
15
28
VO(PP)
Maximum peak-to-peak output
voltage swing
V
26
26
Large signal differential voltage
Large-signal differential voltage
amplification
am lification
200
200
AVD
V/mV
rI
Input resistance
25
°
C
25
°
C
Full range
25
°
C
Full range
25
°
C
1.5
80
80
80
80
4
0.5
70
70
70
70
2
Μ
CMRR
Common mode rejection ratio
Common-mode rejection ratio
VIC= VICRmin
VIC = VICRmin
98
90
dB
kSVR
Supply voltage rejection ratio
(
VCC/
VIO)
98
96
dB
No load,
VO = 0,
See Note 6
1.8
3
1.8
3
ICC
Supply current
MAX
1.2
2.5
mA
All characteristics are measured under open-loop conditions with zero common-mode input voltage unless otherwise specified. Full range for
LM107 is –55
°
C to 125
°
C, for LM207 is –25
°
C to 85
°
C, and for LM307 is 0
°
C to 70
°
C.
NOTES: 5. Unless otherwise noted VCC
±
=
±
5 V to
±
20 V for LM107 and LM207, and VCC
±
=
±
5 V to
±
15 V for LM307. All typical values are
at VCC
±
=
±
15 V.
6. For the LM107 and LM207, VCC
±
=
±
20 V. For the LM307, VCC
±
=
±
15 V.