SLOS066R SEPTEMBER 1975 REVISED JANUARY 2005
5
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
LM2902
ALL OTHER
DEVICES
UNIT
Supply voltage, VCC (see Note 1)
Differential input voltage, VID (see Note 2)
Input voltage, VI (either input)
Duration of output short circuit (one amplifier) to ground at (or below) TA = 25
°
C,
VCC
≤
15 V (see Note 3)
±
13 or 26
±
26
0.3 to 26
±
16 or 32
±
32
0.3 to 32
V
V
V
Unlimited
Unlimited
D package
86
86
DB package
96
96
Package thermal impedance,
θ
JA (see Notes 4 and 5)
N package
80
80
°
C/W
NS package
76
76
PW package
113
113
FK package
5.61
Package thermal impedance, JC (see Notes 6 and 7)
J package
15.05
°
C/W
W package
14.65
Operating virtual junction temperature, TJ
Case temperature for 60 seconds
150
150
°
C
°
C
°
C
°
C
FK package
260
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds
J or W package
300
300
Storage temperature range, Tstg
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES:
1. All voltage values (except differential voltages and VCC specified for the measurement of IOS) are with respect to the network GND.
2. Differential voltages are at IN+, with respect to IN.
3. Short circuits from outputs to VCC can cause excessive heating and eventual destruction.
4. Maximum power dissipation is a function of TJ(max), JA, and TA. The maximum allowable power dissipation at any allowable
ambient temperature is PD = (TJ(max) TA)/JA. Operating at the absolute maximum TJ of 150
°
C can affect reliability.
5. The package thermal impedance is calculated in accordance with JESD 51-7.
6. Maximum power dissipation is a function of TJ(max), JC, and TC. The maximum allowable power dissipation at any allowable case
temperature is PD = (TJ(max) TC)/JC. Operating at the absolute maximum TJ of 150
°
C can affect reliability.
7. The package thermal impedance is calculated in accordance with MIL-STD-883.
65 to 150
65 to 150
ESD protection
TEST CONDITIONS
TYP
±
2
UNIT
Human-Body Model
LM224K, LM224KA, LM324K, LM324KA, LM2902K, LM2902KV, LM2902KAV