Copyright 2007 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree and the
Cree logo are registered trademarks of Cree, Inc.
2
CLD-CT2.000
Cree, Inc.
4600 Silicon Drive
Durham, NC 27703
USA Tel: +1.919.313.5300
Fax: +1.919.313.5778
www.cree.com/ledlamps
Standard Bins for LP476PBL-90G-03 (I
F
= 30 mA)
Lamps are sorted to luminous intensity (I
V
), V
F
and dominant wavelength (λ
D
) bins shown.
Orders for LP476PBL1-90G-03 may be filled with any or all bins contained as below.
All luminous intensity (I
V
), V
F
and dominant wavelength (λ
D
) values shown and specified are at I
F
= 30 mA.
X3
X4
X5
T or
above
S
R
Q
Forward Voltage (V
F
)
Rank
Voltage
V7
V8
V9
V10
V11
V12
V13
V14
2.8-3.0 V
3.0-3.2 V
3.2-3.4 V
3.4-3.6 V
3.6-3.8 V
3.8-4.0 V
4.0-4.2 V
4.2-4.4 V
Important Notes:
All ranks will be included per delivery; rank ratio will be based on the dice distribution.
Tolerance of measurement of luminous intensity is ±15%.
Tolerance of measurement of dominant wavelength is ±1 nm.
Tolerance of measurement of V
is ±0.05 V.
Packaging methods are available for selection; please refer to the “Cree LED Lamp Packaging Standard” docu-
ment.
Please refer to the “Cree LED Lamp Reliability Test Standards” document for reliability test conditions.
Please refer to the “Cree LED Lamp Soldering & Handling” document for information about how to use this LED
product safely.
1.
2.
3.
4.
5.
6.
7.
460 nm
465 nm
470 nm
475 nm
Dominant Wavelength (λ
D
)
L
V
)
1100 mcd
770 mcd
550 mcd
390 mcd