ASIA
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Fwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
EUROPE
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44 (1384) 843-355
AMERICAS
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
129
www.astecpower.com
Ordering Information
5.0 (127.0)
2.5
(63.5)
3.5
(88.9)
1.18 (30.0)
Optional
(-CEF)
Cover
with fan
9.0
(228.6)
6.64
(168.6)
3.42 (87.0)
.79
(20)
SK1
3 2 1
SK5
+ve -ve
Terminal
Block TB1
SK4 fan
#6-32 UNC (8 places)
.24 (6.1)
5.46
(138.6)
8.52
(216.4)
M3 (4 places)
3.68
(93.6)
3.15
(80)
2.17
(55)
.55
(14)
1.30
(33.0)
Optional
(-CF)
Cover
with Fan
10.78
(273.8)
J1
6-32 (2 places)
Main Output
SK3
1234 5 678910
SK6
Top pot.
=V4 adjust
Bottom pot.
=V1 adjust
SK2
6 5 4 3 2 1
6-32 (3 places)
M3
(6 places)
Model
Number
Output
Voltage
Minimum
Load
Maximum Load with
30 CFM Forced Air
Peak
Load
1
Regulation
2
Ripple
P/P (PARD)
3
LPQ352-C
+5 V
+12 V
-12 V
3.3-24 V
5 A
0 A
0 A
*1 A
50 A
12 A
6 A
6 A
60 A
14 A
8 A
8 A
±2%
±3%
±3%
±3%
50 mV
120 mV
120 mV
240 mV, max.
LPQ353-C
+5 V
+15 V
-15 V
3.3-24 V
5 A
0 A
0 A
*1 A
50 A
12 A
6 A
6 A
60 A
14 A
8 A
8 A
±2%
±3%
±3%
±3%
50 mV
150 mV
150 mV
240 mV, max.
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 μF in parallel with a 0.1 μF capacitor at rated line voltage and load ranges.
4. 4th output 3.3-24 V factory set at 5 V.
5. * Minimum load required when the output is set below 5 volts.
6. If optional CF or CEF fans are not used, 30CFM forced air cooling needs to be provided and is required through the
length of the power supply. Not convection rated.
7. Remote inhibit resets OVP latch
Note: -CF suffix added to the model number indicates cover with fan,
-CEF suffix added to model number indicates end-mounted fan chassis.
SK1
PIN 1
PIN 2
PIN 3
PIN 1
PIN 2
PIN 3
PIN 4
PIN 5
PIN 6
PIN 1
PIN 2
PIN 3
PIN 4
PIN 5
PIN 6
PIN 7
PIN 8
PIN 9
PIN 10
PIN 1
PIN 2
PIN 1
PIN 2
PIN 1
PIN 2
Neutral
Line
Ground
+12 / 15 V
Common
Common
-12 / 15 V
3.3-25 V RET Float
3.3-25 V Float
+ Sense V 4
- Sense V 4
+Sense V 1
-Sense V 1
POK
C.Share
DC-OK
Inhibit (N.O.)
Inhibit (N.C.)
COM
+ Fan 1 (12V@150mA)
– Common
+ 5V aux (5V@100mA)
– Common
+ Fan 2 (12V@150mA)
– Common
SK2
SK3
SK4
SK5
SK6
Mating Connectors
SK3
Molex: 22-01-1084
PINS: 08-70-0057
Molex 22-01-3027
PINS: 08-50-0114
Molex 22-01-3027
PINS: 08-50-0114
Molex 22-01-3027
PINS: 08-50-0114
SK4
SK5
SK6
Astec Connector Kit #70-841-011, includes all of the above.
Pin Assignments
L
Notes:
1.
2.
3.
4.
Specifications subject to change without notice.
All dimensions in inches (mm), tolerance ±.02”.
Specifications are at factory settings
To enable normally closed Remote Inhibit,
cut Jumper J1.
Mounting maximum insertion depth is 0.12”.
Warranty: 1 year
Weight: 4 lb. / 1.8kg.
5.
6.
7.