Cassette Style
100 Watt AC-DC Converters
S Series PFC
Edition 01/01.2001
6/27
Electrical Output Data
General Conditions
–
T
A
= 25
°
C, unless T
C
is speci
fi
ed.
–
Pin 18 (i) connected to pin 14 (S
–
/Vo1
–
), U
o
adjusted to U
o nom
(option P), R input not connected.
–
Sense line pins 12 (S+) and 14 (S
–
) connected to pins 4 (Vo1+) and 8 (Vo1
–
) respectively.
Table 4a: Output data single output modules
Output
LS 4001
5.1 V
LS 4301
12.0 V
LS 4501
15.0 V
LS 4601
24.0 V
Characteristics
Conditions
min
typ
max
min
typ
max
min
typ
max
min
typ
max
Unit
U
o
Output voltage
U
i nom
, I
o nom
5.07
5.13
11.93
12.07 14.91
15.09 23.86
24.14
V
U
op
Overvoltage protection
(supressor diode)
7.6
21
26.5
43.5
I
o nom
Output current
1
U
i min
...U
i max
T
C min
...T
C max
16.0
8.0
6.5
4.2
A
I
oL
Output current limit
2
U
i min
...U
i max
16.2
8.2
6.7
4.4
u
o 5
Output
voltage
noise
Low frequency U
i nom
, I
o nom
Switching freq.BW = 20 MHz
2
2
2
2
mV
pp
15
5
5
5
Total
50
40
40
40
D
U
o U
Static line regulation
U
i min
...U
i nom
,
U
i nom
...U
i max
,
I
o nom
±
5
±
12
±
15
±
24
mV
D
U
o I
Static load regulation
U
i nom
, I
o
=
(0.1...1) I
o nom
20
24
30
48
u
o d 3
Dynamic Voltage
load
regulat.
U
i nom
, I
o
=
I
o nom
1
/
2
I
o nom
±
170
±
150
±
150
±
100
deviation
Recovery timeIEC/EN 61204
t
d 3
a
Uo
0.3
0.4
0.4
0.3
ms
Temperature coefficient U
i min
...U
i max
of output voltage
4
–
0.5
-1.5
-1.5
1.5
mV/K
0...I
o nom
1
If the output voltages are increased above U
o nom
through R-input control, option P setting, remote sensing or option T, the output cur-
rents should be reduced accordingly so that P
o nom
is not exceeded.
2
See: Output Voltage Regulation of Single or Double Output Modules with Outputs 1 and 2 Connected in Series.
3
See: Typical dynamic load regulation of U
o1
and U
o2.
4
Negative temperature coef
fi
cient (0...
–
3 mV/cell and K) available on request.
5
Measured according to IEC/EN 61204 sub clause 3.10 with a probe acc. to annex A of the same standards. (See:Technical Informa-
tion: Measuring and Testing)