Cassette Style
100 Watt AC-DC Converters
S Series PFC
Edition 01/01.2001
6/27
Electrical Output Data
General Conditions
–
TA = 25
°C, unless T
C is specied.
– Pin 18 (i) connected to pin 14 (S–/Vo1–),
Uo adjusted to Uo nom (option P), R input not connected.
– Sense line pins 12 (S+) and 14 (S–) connected to pins 4 (Vo1+) and 8 (Vo1–) respectively.
Table 4a: Output data single output modules
Output
LS 4001
LS 4301
LS 4501
LS 4601
5.1 V
12.0 V
15.0 V
24.0 V
Characteristics
Conditions
min
typ
max
min
typ
max
min
typ
max
min
typ
max
Unit
Uo
Output voltage
Ui nom, Io nom
5.07
5.13
11.93
12.07 14.91
15.09 23.86
24.14
V
Uop
Overvoltage protection
7.6
21
26.5
43.5
(supressor diode)
Io nom
Output current 1
Ui min...Ui max
16.0
8.0
6.5
4.2
A
TC min...TC max
IoL
Output current limit 2
Ui min...Ui max
16.2
8.2
6.7
4.4
uo 5
Output
Low frequency
Ui nom, Io nom
22
2
mVpp
voltage
Switching freq.
IEC/EN 61204
15
5
noise
Total
BW = 20 MHz
50
40
DUo U Static line regulation
Ui min...Ui nom,
±5
±12
±15
±24 mV
Ui nom...Ui max,
Io nom
DUo I
Static load regulation
Ui nom, Io =
202430
48
(0.1...1)
Io nom
uo d 3
Dynamic Voltage
Ui nom, Io =
±170
±150
±100
load
deviation
Io nom 1/2 Io nom
t d 3
regulat.
Recovery time
IEC/EN 61204
0.3
0.4
0.3
ms
aUo
Temperature coefficient
Ui min...Ui max
–0.5
-1.5
1.5
mV/K
of output voltage 4
0...
Io nom
1 If the output voltages are increased above Uo nom through R-input control, option P setting, remote sensing or option T, the output cur-
rents should be reduced accordingly so that
Po nom is not exceeded.
2 See: Output Voltage Regulation of Single or Double Output Modules with Outputs 1 and 2 Connected in Series.
3 See: Typical dynamic load regulation of Uo1 and Uo2.
4 Negative temperature coefcient (0...–3 mV/cell and K) available on request.
5 Measured according to IEC/EN 61204 sub clause 3.10 with a probe acc. to annex A of the same standards. (See:Technical Informa-
tion: Measuring and Testing)