LT1014, LT1014A, LT1014D
QUAD PRECISION OPERATIONAL AMPLIFIERS
SLOS039C – JULY 1989 – REVISED SEPTEMBER 1999
4
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage (see Note 1): V
CC+
22 V
–22 V
±
30 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V
CC–
Differential input voltage (see Note 2)
Input voltage range, V
I
(any input) (see Note 1)
Duration of short-circuit current at (or below) T
A
= 25
°
C (see Note 3)
Continuous total power dissipation
Operating free-air temperature range, T
A
: LT1014C, LT1014DC
V
CC–
– 5 V to V
CC+
Unlimited
. . . . . . . . . . . . . . . . . . . . . . . . .
See Dissipation Rating Table
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
LT1014M, LT1014AM, LT1014DM
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
–0
°
C to 70
°
C
–40
°
C to 105
°
C
–55
°
C to 125
°
C
LT1014I, LT1014DI
. . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds: J package
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds: DW or N package
Case temperature for 60 seconds: FK package
Storage temperature range, T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES:
1. All voltage values, except differential voltages, are with respect to the midpoint between VCC+ and VCC–.
2. Differential voltages are at the noninverting input with respect to the inverting input.
3. The output may be shorted to either supply.
300
°
C
260
°
C
260
°
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
–65
°
C to 150
°
C
DISSIPATION RATING TABLE
PACKAGE
TA
≤
25
°
C
POWER RATING
DERATING FACTOR
ABOVE TA = 25
°
C
8.2 mW/
°
C
11.0 mW/
°
C
11.0 mW/
°
C
9.2 mW/
°
C
TA = 70
°
C
POWER RATING
TA = 105
°
C
POWER RATING
TA = 125
°
C
POWER RATING
DW
1025 mV
656 mW
369 mW
205 mW
FK
1375 mV
880 mW
495 mW
275 mW
J
1375 mV
880 mW
495 mW
275 mW
N
1150 mV
736 mW
414 mW
230 mW