12
LY
LY
I
RELAY OPTIONS
LED Indicator
Specifications and dimensions same as the Standard Type with the following exception. With the LED indicator type, the rated current
is approximately 0 to 5.0 mA higher than the Standard Type.
Terminal arrangement/Internal connections
(Bottom view)
LY2N
DC coil rating type
AC coil rating type
Note:
1. The coil terminals 10 and 11 of Type LY3N become (-) and (+) and terminals 13 and 14 of Type LY4N become (-) and (+),
respectively.
2. Pay special attention to the polarities when using the DC type.
Diode Surge Suppression
Specifications and dimensions same as the Standard Type with the following exception. Ambient operating temperature: -25
°
to 40
°
C
(-13
°
to 104
°
F)
Without Diode
With Diode
Terminal arrangement/Internal connections
(Bottom view)
LY2(N)-D(2)
LY2-D
6, 12, 24, 48
100/110 VDC
LY2N-D2
6, 12, 24, 48 VDC
LY2N-D2
100/110 VDC
Note:
1. Pay special attention to the polarities when using the DC type.
2. The release time is somewhat longer, but satisfies the standard specifications of 25 ms.
3. The reverse-breakdown voltage of the diode is 1,000 VDC.
4. Available on DC versions only.