MITSUBISHI(Standard Linear ICs)
M62295GP
PC BACK- LIGHT CONTROL IC
( / 7 )
6
Note 1. Timer-latch time refers to the time under Cscp=1uF, Cscp2=0.1uF.
2. Amp. output is "H" when tube current I0 equals to 0, "L" when it is at
its minimum. Detection voltage is 2.5V("H" side), 0.25V("L" side).
Table 1. Protection operation mode at a glance
Timer-L (Cscp2) = Cscp2 *
Cscp1 :
Terminal for capacitance for timer-latch set (few sec.)
Timer-L (Cscp1) = Cscp1 *
2.5
1.3 * 10
-6
Cscp2 :
Terminal for capacitance for timer-latch set (few msec.)
1.25
1.3 * 10
-6
Application for timer-latch by detecting tube current
and feecback voltage is available by using Iscp,
Cscp1, Cscp2 terminal.
Two kinds of setting for timer-latch time is available
by the setting of Cscp1, Cscp2. Each timer-latch
time is set by the formula below.
2sec
10msec
Ampout="H" Ampout="L"
Io=0
Io=Max
Io=0
Io=Max
Io=0
Protection function (timer-latch) (Cscp1, Cscp2, Iscp)
Iscp
BL tube current detection
Cscp1
Cscp1
Cscp2
Cscp2
Fig.7 Connections of Cscp1, Cscp2
Fig.8 Connections of Iscp terminal
Operation state
Protection
operation mode
Normal start-up
Timer-latch time
Start-up in
shortcircuited state
Start-up in black
mode
Start-up in open state
Shortcircuit while
in operation
Open while in operation
Operation stop after 10ms
Operation stop instantaneously
Operation stop after 2sec.
Operation stop after 2sec.
ON
OFF
Normal start-up if turn-on
is made within 2sec.
Operation stop instantaneously
Operation stop instantaneously
Operation stop instantaneously
Triggers for protection operation
Detection of tube current
Detection of tube current is made by Iscp terminal.
Detection voltage for Iscp terminal is set 1.25V.
After power is on, when Iscp voltage does not rise
up to 1.25V by timer-L(Cscp1) time, or when Iscp
voltage becomes 1.25V or less after start-up,
abnormality is detected to move on to the protection
operation mode in Fig.1.
If Iscp voltage is less than 1.25V, light control is
not made(100%).
Detection of feedback voltage
Detection of feedback voltage is made by FB
terminal.
When FB terminal voltage goes down to FB low
detection voltage (0.25V) or less, or when it rise up
to FB terminal high detection voltage or more,
abnormality is detected to move on to the protection
operation mode in Fig.1.