M62343GP
REJ03F0075-0200 Rev.2.00 Jun 15, 2007
Page 3 of 7
Absolute Maximum Ratings
Item
Symbol
Rated Value
–0.3 to 7.0
–0.3 to V
CC
+0.3
≤
7.0
–0.3 to V
CC
+0.3
≤
7.0
200
–20 to +85
–55 to +125
Unit
V
V
V
mW
°C
°C
Power supply voltage
Input voltage
Output voltage
Internal power consumption
Operating ambient temperature
Storage temperature
Electrical Characteristics
V
CC
Vin
V
O
Pd
Topr
Tstg
(Unless specified otherwise, V
CC
= +5 V ±10%, GND = 0 V, Ta = -20oC to 85oC)
Specification Values
Min
Typ
Max
Unit
2.7
5.0
5.5
V
0
0.8
2.7
mA
Item
Symbol
V
CC
I
CC
Test Conditions
Power supply voltage
Power supply current
At CLK = 1 MHz operation, I
AO
= 0
μ
A
D/A data: 6 Ah (at maximum current)
DI = CLK = LD = GND, I
AO
= 0
μ
A
V
IN
= 0 to V
CC
I
AO
= ±100
μ
A
I
AO
= ±500
μ
A
Upper saturation voltage = 0.3 V
Lower saturation voltage = 0.2 V
V
CC
= 5.12 V (20 mV/LSB)
No load (I
AO
= 0)
0
0.6
—
—
—
—
—
—
1.8
10
0.2Vcc
Vcc
Vcc
0.1
Vcc
0.2
1.0
Input leakage current
Input voltage “L”
Input voltage “H”
Buffer amp output
voltage range
Buffer amp output
drive range
Differential
nonlinearity error
Nonlinearity error
Zero point error
Full-scale error
Oscillation limit output
capacitance
Buffer amp output
impedance
AC Characteristics
I
ILK
V
IL
V
IH
V
AO
–10
0
0.5Vcc
0.1
0.1
–1.0
μ
A
V
V
V
I
AO
mA
S
DL
–1.0
—
1.0
LSB
S
L
S
ZERO
S
FULL
C
O
–1.5
–2.0
–2.0
—
—
—
—
1.5
2.0
2.0
0.1
LSB
LSB
LSB
μ
F
R
O
—
5.0
—
(Unless specified otherwise, V
CC
= +5 V ±10%, GND = 0 V, Ta = -20oC to 85oC)
Specification Values
Min
Typ
Max
Unit
200
—
—
ns
200
—
—
ns
—
—
200
ns
—
—
200
ns
30
—
—
ns
60
—
—
ns
200
—
—
ns
100
—
—
ns
100
—
—
ns
—
—
300
μ
s
Item
Symbol
t
CKL
t
CKH
t
CR
t
CF
t
DCH
t
CHD
t
CHL
t
LDC
t
LDH
t
LDD
Test Conditions
Clock “L” pulse width
Clock “H” pulse width
Clock rise time
Clock fall time
Data setup time
Data hold time
Load setup time
Load hold time
Load “H” pulse width
D-A output settling time
Until output reaches last 1/2 LSB