MAX11800–MAX11803
Low-Power, Ultra-Small Resistive Touch-Screen
Controllers with I2C/SPI Interface
______________________________________________________________________________________
51
BIT
765432
1
0
NAME
T_SAMPLE_X[1:0]
T_SAMPLE_Y[1:0]
T_SAMPLE_Z1[1:0]
T_SAMPLE_Z2[1:0]
DEFAULT
0
BIT
NAME
DESCRIPTION
MAX11800/
MAX11801
MAX11802/
MAX11803
7:6
T_SAMPLE_X[1:0]
Yes
5:4
T_SAMPLE_Y[1:0]
Yes
3:2
T_SAMPLE_Z1[1:0]
Yes
1:0
T_SAMPLE_Z2[1:0]
Sampling time for X, Y, Z1 or Z2 measurements
00: 4 x (2MHz oscillator clock period) = 2μs
01: 16 x (2MHz oscillator clock period) = 8μs
10: 64 x (2MHz oscillator clock period) = 32μs
11: 256 x (2MHz oscillator clock period) = 128μs
Yes
ADC Sampling Time Configuration Register (0x04)*
*
Time ADC spends sampling panel before starting conversion process. This time plus the ADC conversion time determines the sam-
pling rate within averaging operations. Be sure to allow adequate time to settle the ADC capacitors given the panel effective source
resistance.
BIT
7
6
5
4
3
2
1
0
NAME
AVG_X[1:0]
AVG_Y[1:0]
AVG_Z1[1:0]
AVG_Z2[1:0]
DEFAULT
0
BIT
NAME
DESCRIPTION
MAX11800/
MAX11801
MAX11802/
MAX11803
7:6
AVG_X[1:0]
Yes
5:4
AVG_Y[1:0]
Yes
3:2
AVG_Z1[1:0]
Yes
1:0
AVG_Z2[1:0]
Averaging sample depth for X, Y, Z1, or Z2 measurements
If AVG_FLT = 0 (see the Operating Mode Configuration
Register (0x0B) section)
00: Single sample, no averaging
01: Take four samples, average two median samples
10: Take eight samples, average four median samples
11: Take 16 samples, average eight median samples
If AVG_FLT = 1 (see the Operating Mode Configuration Register
(0x0B) section)
00: Single sample, no averaging
01: Take four samples, average all samples
10: Take eight samples, average all samples
11: Take 16 samples, average all samples
Yes
Measurement Averaging Configuration Register (0x03)*
*
The settings can be enabled and disabled through settings in the operating mode configuration register (0x0B), allowing for dynamic
configuration of averaging modes depending on operating mode.