MC10EL52, MC100EL52
http://onsemi.com
3
Table 4. 10EL SERIES PECL DC CHARACTERISTICS VCC = 5.0 V; VEE = 0 V (Note 2) 40°C
25°C
85°C
Symbol
Characteristic
Min
Typ
Max
Min
Typ
Max
Min
Typ
Max
Unit
IEE
Power Supply Current
21
25
21
25
21
25
mA
VOH
Output HIGH Voltage (Note
6)3920
4010
4110
4020
4105
4190
4090
4185
4280
mV
VOL
Output LOW Voltage (Note
3)3050
3200
3350
3050
3210
3370
3050
3227
3405
mV
VIH
Input HIGH Voltage (SingleEnded)
3770
4110
3870
4190
3940
4280
mV
VIL
Input LOW Voltage (SingleEnded)
3050
3500
3050
3520
3050
3555
mV
VIHCMR
Input HIGH Voltage Common Mode
Range (Differential Configuration) (Note
4)D
CLK
3.4
2.5
4.6
4.4
3.4
2.5
4.6
4.4
3.4
2.5
4.6
4.4
V
IIH
Input HIGH Current
150
mA
IIL
Input LOW Current
0.5
0.3
mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
2. Input and output parameters vary 1:1 with VCC.
VEE can vary +0.25 V / 0.5 V for +25°C and +85°C. or VEE can vary +0.06 V / 0.5 V for 40°C.
3. Outputs are terminated through a 50 ohm resistor to VCC 2.0 V.
4. VIHCMR min varies 1:1 with VEE, VIHCMR max varies 1:1 with VCC. The VIHCMR range is referenced to the most positive side of the differential input
signal. Normal operation is obtained if the HIGH level falls within the specified range and the peak-to-peak voltage lies between VPPmin and 1 V.
Table 5. 10EL SERIES NECL DC CHARACTERISTICS VCC = 0 V; VEE = 5.0 V (Note 5) 40°C
25°C
85°C
Symbol
Characteristic
Min
Typ
Max
Min
Typ
Max
Min
Typ
Max
Unit
IEE
Power Supply Current
21
25
21
25
21
25
mA
VOH
Output HIGH Voltage (Note
6)1080
990
890
980
895
810
910
815
720
mV
VOL
Output LOW Voltage (Note
6)1950 1800 1650 1950 1790 1630 1950 1773 1595
mV
VIH
Input HIGH Voltage (SingleEnded)
1230
890
1130
810
1060
720
mV
VIL
Input LOW Voltage (SingleEnded)
1950
1500 1950
1480 1950
1445
mV
VIHCMR
Input HIGH Voltage Common Mode
Range (Differential Configuration) (Note
4)D
CLK
1.6
2.5
0.4
0.6
1.6
2.5
0.4
0.6
1.6
2.5
0.4
0.6
V
IIH
Input HIGH Current
150
mA
IIL
Input LOW Current
0.5
0.3
mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
5. Input and output parameters vary 1:1 with VCC.
VEE can vary +0.25 V / 0.5 V for +25°C and +85°C. or VEE can vary +0.06 V / 0.5 V for 40°C.
6. Outputs are terminated through a 50 ohm resistor to VCC 2.0 V.
7. VIHCMR min varies 1:1 with VEE, VIHCMR max varies 1:1 with VCC. The VIHCMR range is referenced to the most positive side of the differential input
signal. Normal operation is obtained if the HIGH level falls within the specified range and the peak-to-peak voltage lies between VPPmin and 1 V.