MC10H642, MC100H642
http://onsemi.com
4
Table 5. 10H/100H TTL DC CHARACTERISTICS (VT = VE = 5.0 V ± 5%)
Symbol
Characteristic
Condition
TA = 0°C
TA = 25°C
TA = 85°C
Unit
Min
Max
Min
Max
Min
Max
VIH
VIL
Input HIGH Voltage
Input LOW Voltage
2.0
0.8
2.0
0.8
2.0
0.8
V
IIH
Input HIGH Current
VIN = 2.7 V
VIN = 7.0 V
20
100
20
100
20
100
mA
IIL
Input LOW Current
VIN = 0.5 V
0.6
mA
VOH
Output HIGH Voltage
IOH = 3.0 mA
IOH = 15 mA
2.5
2.0
2.5
2.0
2.5
2.0
V
VOL
Output LOW Voltage
IOL = 24 mA
0.5
V
VIK
Input Clamp Voltage
IIN = 18 mA
1.2
V
IOS
Output Short Circuit Current
VOUT = 0 V
100
225
100
225
100
225
mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
Table 6. AC CHARACTERISTICS (VT = VE = 5.0 V ± 5%)
TA = 0°C
TA = 25°C
TA = 85°C
Symbol
Characteristic
Condition
Min
Max
Min
Max
Min
Max
Unit
tPLH
Propagation Delay
D to Output
Q2Q7
C ECL
C TTL
CL = 25 pF
4.70
5.70
4.75
5.75
4.60
4.50
5.60
5.50
ns
tskpp
ParttoPart Skew
1.0
ns
tskwd*
WithinDevice Skew
0.5
ns
tPLH
Propagation Delay
D to Output
Q0, Q1
C ECL
C TTL
CL = 25 pF
4.30
5.30
4.50
5.50
4.25
5.25
ns
tskpp
ParttoPart Skew
All
Outputs
CL = 25 pF
2.0
ns
tskwd
WithinDevice Skew
CL = 25 pF
1.0
ns
tPD
Propagation Delay
R to Output
All
Outputs
CL = 25 pF
4.3
6.3
4.0
6.0
4.5
6.5
ns
tR
tF
Output Rise/Fall Time
0.8 V to 2.0 V
All
Outputs
CL = 25 pF
2.5
ns
fMAX**
Maximum Input Frequency
CL = 25 pF
100
MHz
RPW
Reset Pulse Width
1.5
ns
RRT
Reset Recovery Time
1.25
ns
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
* WithinDevice Skew defined as identical transactions on similar paths through a device.
**MAX Frequency is 135 MHz.