Table 2. DC CHARACTERISTICS (VCC = 5.0 V, VEE = 0 V)
Symbol
Characteristic
-40°C
25°C
85°C
Unit
Min
Typ Max Min
Typ Max
VOH
Output Voltage High (QR,QR)
VCC =5.0 V, GND = 0 V (Notes 1, 2)
3.92 4.05 4.22 3.97 4.11 4.27 4.00 4.16 4.30
V
VOL
Output Voltage Low (QR,QR)
VCC =5.0 V, GND = 0 V (Notes 1, 2)
3.05 3.23 3.35 3.07 3.24 3.37 3.10 3.25 3.41
V
VOH
Output Voltage High (QT,QT)
VCC =5.0 V, GND = 0 V (Notes 1, 3)
3.83 3.95 4.10 3.88 4.02 4.15 3.90 4.09 4.17
V
VOL
Output Voltage Low (QT,QT)
VCC =5.0 V, GND = 0 V (Notes 1, 3)
1.90 2.33 2.50 1.85 2.26 2.45 1.85 2.23 2.45
V
ICC
Quiescent Supply Current (Note 4)
20
25
42
23
27
47
25
28
47
mA
VIH
Input Voltage High (DR,DR & DT,DT)
VCC = 5.0 V, GND = 0 V (Note 1)
3.77
4.11 3.87
4.19 3.94
4.28
V
VIL
Input Voltage Low (DR,DR & DT,DT)
VCC = 5.0 V, GND = 0 V (Note 1)
3.05
3.50 3.05
3.52 3.05
3.56
V
VIH
Input Voltage High SEL
2.0
V
VIL
Input Voltage Low SEL
0.8
V
VBB
Output Reference Voltage
VCC = 5.0 V, GND = 0 V (Note 1)
3.57 3.63 3.70 3.65 3.70 3.75 3.69 3.75 3.81
V
IIH
Input HIGH Current
150
mA
IIL
Input LOW Current
0.5
mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
1. Values will track 1:1 with the VCC supply. VEE can vary +0.5 V to 0.5 V.
2. Outputs loaded with 50 W to VCC 2.0 V.
3. Outputs loaded with 50 W to VCC 3.0 V.
4. Outputs open circuited.