MC74AC374 MC74ACT374
5-3
FACT DATA
DC CHARACTERISTICS
Symbol
Parameter
(V)
74AC
74AC
Unit
Conditions
VCC
TA = +25
°
C
TA =
–40
°
C to +85
°
C
Typ
Guaranteed Limits
VIH
Minimum High Level
Input Voltage
3.0
4.5
5.5
1.5
2.25
2.75
2.1
3.15
3.85
2.1
3.15
3.85
VOUT = 0.1 V
or VCC – 0.1 V
V
VIL
Maximum Low Level
Input Voltage
3.0
4.5
5.5
1.5
2.25
2.75
0.9
1.35
1.65
0.9
1.35
1.65
VOUT = 0.1 V
or VCC – 0.1 V
V
VOH
Minimum High Level
Output Voltage
3.0
4.5
5.5
2.99
4.49
5.49
2.9
4.4
5.4
2.9
4.4
5.4
IOUT = –50
μ
A
V
V
*VIN = VIL or VIH
3.0
4.5
5.5
2.56
3.86
4.86
2.46
3.76
4.76
–12 mA
–24 mA
–24 mA
IOH
VOL
Maximum Low Level
Output Voltage
3.0
4.5
5.5
0.002
0.001
0.001
0.1
0.1
0.1
0.1
0.1
0.1
IOUT = 50
μ
A
V
V
*VIN = VIL or VIH
3.0
4.5
5.5
0.36
0.36
0.36
0.44
0.44
0.44
12 mA
24 mA
24 mA
IOL
IIN
Maximum Input
Leakage Current
5.5
±
0.1
±
1.0
μ
A
VI = VCC, GND
IOZ
Maximum
Current
VI (OE) = VIL, VIH
VI = VCC, GND
VO = VCC, GND
VOLD = 1.65 V Max
3-State
5.5
±
0.5
±
5.0
μ
A
IOLD
Minimum Dynamic
Output Current
5.5
75
mA
IOHD
5.5
–75
mA
VOHD = 3.85 V Min
ICC
Maximum Quiescent
Supply Current
5.5
8.0
80
μ
A
VIN = VCC or GND
* All outputs loaded; thresholds on input associated with output under test.
Maximum test duration 2.0 ms, one output loaded at a time.
Note: IIN and ICC @ 3.0 V are guaranteed to be less than or equal to the respective limit @ 5.5 V VCC.