MCM6208C
3
MOTOROLA FAST SRAM
CAPACITANCE
(f = 1 MHz, dV = 3 V, TA = 25
°
C, Periodically Sampled Rather Than 100% Tested)
Characteristic
Symbol
Max
Unit
Address Input Capacitance
Cin
Cin
CI/O
6
pF
Control Pin Input Capacitance (E, G, W)
6
pF
I/O Capacitance
8
pF
AC OPERATING CONDITIONS AND CHARACTERISTICS
(VCC = 5.0 V
±
10%, TA = 0 to + 70
°
C, Unless Otherwise Noted)
Input Timing Measurement Reference Level
Input Pulse Levels
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input Rise/Fall Time
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.5 V
. . . . . . . . . . . . . . .
0 to 3.0 V
5 ns
Output Timing Measurement Reference Level
Output Load
. . . . . . . . . . . . . . . .
1.5 V
. . . . . . . . . . . . .
Figure 1A Unless Otherwise Noted
READ CYCLE
(See Notes 1 and 2)
– 12
– 15
– 20
– 25
–35
Parameter
Symbol
Min
Max
Min
Max
Min
Max
Min
Max
Min
Max
Unit
Notes
Read Cycle Time
tAVAV
tAVQV
tELQV
tGLQV
tAXQX
tELQX
tEHQZ
tGLQX
tGHQZ
tELICCH
tEHICCL
12
—
15
—
20
—
25
—
35
—
ns
2
Address Access Time
—
12
—
15
—
20
—
25
—
25
ns
Enable Access Time
—
12
—
15
—
20
—
25
—
25
ns
3
Output Enable Access Time
—
6
—
8
—
10
—
12
—
—
ns
Output Hold from Address Change
4
—
4
—
4
—
4
—
4
—
ns
Enable Low to Output Active1
4
—
4
—
4
—
4
—
4
—
ns
4, 5, 6
Enable High to Output High–Z
0
6
0
8
0
9
0
10
0
10
ns
4, 5, 6
Output Enable Low to Output Active
0
—
0
—
0
—
0
—
0
—
ns
4, 5, 6
Output Enable High to Output High–Z
0
6
0
7
0
8
0
10
0
—
ns
4, 5, 6
Power Up Time
0
—
0
—
0
—
0
—
0
—
ns
Power Down Time
—
12
—
15
—
20
—
25
—
35
ns
NOTES:
1. W is high for read cycle.
2. All timings are referenced from the last valid address to the first transitioning address.
3. Addresses valid prior to or coincident with E going low.
4. At any given voltage and temperature, tEHQZ max is less than tELQX min, and tGHQZ max is less than tGLQX min, both for a given device
and from device to device.
5. Transition is measured
±
500 mV from steady–state voltage with load of Figure 1B.
6. This parameter is sampled and not 100% tested.
7. Device is continuously selected (E1
≤
VIL).
AC TEST LOADS
Figure 1A
Figure 1B
The table of timing values shows either a
minimum or a maximum limit for each param-
eter. Input requirements are specified from
the external system point of view. Thus, ad-
dress setup time is shown as a minimum
since the system must supply at least that
much time (even though most devices do not
require it). On the other hand, responses from
the memory are specified from the device
point of view. Thus, the access time is shown
as a maximum since the device never pro-
vides data later than that time.
TIMING LIMITS
OUTPUT
Z0 = 50
RL = 50
VL = 1.5 V
5 pF
+ 5 V
OUTPUT
255
480