Thermoelectric Cooler
Performance Curves
MI3026T
Copyright 2000, Marlow Industries, Inc. Marlow Industries reserves the right to change the design and specifications of products without notice. 102-0022, Rev F
Environment: One atmosphere dry nitrogen
Hot Side Temperature: 27°C
0.0
1.0
2.0
3.0
4.0
V
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4
CURRENT (AMPS)
0.0
20.0
40.0
60.0
80.0
100.0
120.0
T
Q=0
T=0
HEAT
LOAD
(WATTS)
0.00
0.10
0.20
0.30
0.40
0.50
0.60
0.0
1.0
2.0
3.0
4.0
V
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4
CURRENT (AMPS)
0.0
20.0
40.0
60.0
80.0
100.0
120.0
T
Q=0
T=0
HEAT
LOAD
(WATTS)
0.00
0.10
0.20
0.30
0.40
0.50
0.60
0.70
Hot Side Temperature: 50°C
For performance information in a vacuum or with hot side temperatures other than 27°C or 50°C, consult one of our
Applications Engineers.
Installation
Recommended mounting methods: Bonding with thermal epoxy or soldering with metallized ceramics. For additional
information, please refer to our TEC Installation Guide.
Operation Cautions
For maximum reliability, storage and operation below 85°C in a non-condensing environment is recommended. To
minimize thermal stress, use linear/proportional temperature control or a similar method rather than an ON/OFF method.
Addresses
Marlow Industries, Inc.
10451 Vista Park Road
Dallas Texas 75238-1645
214-340-4900 (tel)
214-341-5212 (fax)
II-VI Japan Inc.
WBG Marive East 17F
2-6 Nakase, Mihama-ku
Chiba-Shi, Chiba 261-7117
Japan
81 43 297 2693 (phone)
81 43 297 3003 (fax)
center@ii-vi.co.jp
www.ii-vi.co.jp
Marlow Industries Europe
Aberdeen House, South Road
Haywards Heath
West Sussex RH164NG UK
+44 (0)1444-443404 (tel)
+44 (0)1444-443334(fax)
II-VI Singapore Pte., Ltd.
Blk. 5012, Techplace II
#04-07 & 05-07/12, Ang Mo Kio Ave. 5
Singapore 569876
(65) 6481 8215 (phone)
(65) 6481 8702 (fax)
info@ii-vi.com.sg
www.ii-vi.com.sg
II-VI Optics (Suzhou) Co., Ltd.
No. 12, Sutong Road
Suzhou Industrial Park
Suzhou, China 215021
(86) 512 6761 9295 (phone)
(86) 512 6761 5049 (fax)
twosix@ii-vi.com.cn
www.ii-vi.com.cn