DO NOT
SCALE FROM
THIS PRINT
UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE IN INCHES.
TOLERANCES ARE:
DECIMALS
ANGLES
.XX: .01[.3]
2
.XXX: .005[.13]
.XXXX: .0020[.051]
TOLERANCES DO NOT APPLY
TO REFERENCE DIMENSIONS.
.292
REF (TYP)
7.42
* "C" REF
THIS PRODUCT MANUFACTURED
WITH LEAD-FREE PROCESSING
Pb
ICD-XX-01
ICD-XX-02
SUB-TCF-3850-19-01-XX.XX
(SEE TABLE 1 FOR QTY)
ICD-XX-02
ICD-XX-01
LENGTH: XX.XX + "L" REF (SEE TABLE 4)
"B" REF
(TYP)
"A" REF
(TYP)
.570 14.49
REF (TYP)
.845 21.47
REF (TYP)
LENGTH: XX.XX 01%
'A'
STS-01
(TIGHTEN TO 1.4 - 1.7 IN-LBS)
(4 PLCS)
C1
FIRST END
SECOND END
N (SEE TABLE 3)
2
1
N-1
(SEE TABLE 3)
SUB-MICD-X-XXX-XX
2
1
N-1 (SEE TABLE 3)
N
(SEE TABLE 3)
HDRL-11
(SEE NOTE 5)
DETAIL 'A'
SCALE 2.5 : 1
LENGTH
REF
END OPTION
-F: SCREW OPTION FIRST END ONLY
-B: SCREW OPTION BOTH ENDS
-N: NO CAPS
(SEE FIG. 3, SHEET 5 FOR EDGE MOUNT
END OPTIONS)
(SEE FIG. 4, SHEET 5 FOR DOUBLE
VERTICAL END OPTIONS)
(SEE FIG. 5, SHEET 5 FOR NO CAPS OPTIONS)
(LEAVE BLANK FOR STANDARD CAPS
BOTH ENDS)
-TTR: TERMINAL, TOP, RIGHT
-TTL: TERMINAL, TOP, LEFT
-TBR: TERMINAL, BOTTOM, RIGHT
-TBL: TERMINAL, BOTTOM, LEFT
-STR: SOCKET, TOP, RIGHT
-STL: SOCKET, TOP, LEFT
-SBR: SOCKET, BOTTOM, RIGHT
-SBL: SOCKET, BOTTOM, LEFT
(SEE TABLE 1 & SHEET 3)
-TEU: TERMINAL, EDGE MOUNT, UP
-TED: TERMINAL, EDGE MOUNT, DOWN
-SEU: SOCKET, EDGE MOUNT, UP
-SED: SOCKET, EDGE MOUNT, DOWN
(SEE TABLE 5 & SHEET 4)
-1: PIN 1 TO PIN 1
-2: PIN 1 TO PIN 2
-3: PIN 1 TO PIN N-1
-4: PIN 1 TO PIN N
(SEE TABLE 9, SHEET 6)
WIRING OPTION
SECOND END
FIRST END
-XX.XX (INCHES)
(03.75[95.3] MIN)
(SEE NOTE 2)
(SEE NOTE 8)
LENGTH
-019, -038, -057, -076, -095
(PER ROW)
No OF POSITIONS
MICD-XXX-XX.XX-XXX-XXX-X-X
-TTR: TERMINAL, TOP, RIGHT
-TTL: TERMINAL, TOP, LEFT
-TBR: TERMINAL, BOTTOM, RIGHT
-TBL: TERMINAL, BOTTOM, LEFT
-STR: SOCKET, TOP, RIGHT
-STL: SOCKET, TOP, LEFT
-SBR: SOCKET, BOTTOM, RIGHT
-SBL: SOCKET, BOTTOM, LEFT
(SEE TABLE 1 & SHEET 2)
-TEU: TERMINAL, EDGE MOUNT, UP
-TED: TERMINAL, EDGE MOUNT, DOWN
-SEU: SOCKET, EDGE MOUNT, UP
-SED: SOCKET, EDGE MOUNT, DOWN
(SEE TABLE 5 & SHEET 4)
C
FIG. 1
C3
C2
VERTICAL
(MICD-038-XX.XX-STR-STR-1 SHOWN)
* -DV END OPTIONS ONLY
G
SHEET OF
0.635 HIGH-SPEED COAX CABLE ASSEMBLY
BY:
MICD-XXX-XX.XX-XXX-XXX-X-X
DWG. NO.
DESCRIPTION:
PROPRIETARY NOTE
THIS DOCUMENT CONTAINS INFORMATION
CONFIDENTIAL AND PROPRIETARY TO
SAMTEC, INC. AND SHALL NOT BE REPRODUCED
OR TRANSFERRED TO OTHER DOCUMENTS OR
DISCLOSED TO OTHERS OR USED FOR ANY
PURPOSE OTHER THAN THAT WHICH IT WAS
OBTAINED WITHOUT THE EXPRESSED WRITTEN
CONSENT OF SAMTEC, INC.
DO NOT SCALE DRAWING
KEVIN B
12/11/03
6
1
SHEET SCALE: 1.25:1
F:\DWG\MISC\MKTG\MICD-XXX-XX.XX-XXX-XXX-X-X-MKT.SLDDRW
NOTES:
1.
REPRESENTS A CRITICAL DIMENSION.
2. SUB-TCF LENGTH IS EQUAL TO MICD LENGTH.
3. ALL ASSEMBLIES TO BE 100% ELECTRICALLY TESTED.
4. ALL ASSEMBLIES TO BE 100% HI-POT TESTED AT 300V.
5. TOP SUB-TCF NOT SHOWN IN THIS VIEW FOR CLARITY; HDRL-11
TO BE CENTERED ON LOWER SUB-TCF AS SHOWN; HDRL-11 IS
TO CONTAIN PART NUMBER, SHOP NUMBER, & DATE CODE.
6. FOR SUB-ASSEMBLY AND FINISHED GOOD PACKAGING REQUIREMENTS,
REFERENCE PACKAGING STANDARD CO-HD-WI-3033-M.
7. PARTS TO BE PROCESSED PER SAMTEC ACCEPTABILITY REQUIREMENTS:
HDR-PI-01 "CABLE ASSEMBLY WORKMANSHIP STANDARDS".
8. CABLE LENGTHS LONGER THAN 40.00 INCHES ARE NOT SUPPORTED BY
S.I. TEST DATA.
520 PARK EAST BLVD, NEW ALBANY, IN 47150
PHONE: 812-944-6733
FAX: 812-948-5047
e-Mail: info@SAMTEC.com
code: 55322
REVISION G