2
Johnson Components P.O. Box 1732 Waseca, MN 56093-0832 1-800-247-8256 Fax: 507-835-6287 www.johnsoncomp.com
INCHES (MILLIMETERS)
CUSTOMER DRAWINGS AVAILABLE UPON REQUEST
PART NO.
COLOR
MIL-C-39024/10
105-0201-200
White
-01
105-0202-200
Red
-02
105-0203-200
Black
-03
105-0204-200
Green
-05
105-0206-200
Orange
-06
105-0210-200
Blue
-07
105-0207-200
Yellow
-08
105-0213-200
Gray
-09
105-0212-200
Violet
-10
Tip Jacks
SPECIFICATIONS
Contact: Brass body per QQ-B-626D with
wrap around beryllium copper
spring per QQ-C-553
Finish: Silver
Body: Nylon 6/6 per ASTM D4066
Panel Thickness: Up to .375 (9.05)
RATINGS
Current: 5 amps
Breakdown Voltage: 3500 Vrms minimum
Contact Resistance: 0.005 ohms maximum
Adjacent Jack C: 1 pF nominal
Insulated Standard: Rib-Loc Type
For Standard Tip Plug: .080 (2.00) Diameter
FEATURES:
Machined contact with turret terminal
For military or industrial applications
Closed entry blocks access of probes greater than .085 (2.16)
Nylon UL approved for self extinguishing
GOLD PLATING
JCI PART NO. TO MIL-SPEC. PART NO. CROSS REFERENCE
Insulated Metal Clad: Military Type
For Standard Tip Plug: .080 (2.00) Diameter
FEATURES:
Machined contact with turret terminal
Installs by pressing into mounting hole, no mounting hardware required
Closed entry blocks access or probes greater than .085 (2.16)
Nylon UL approved for self extinguishing
SPECIFICATIONS
Contact: Brass per QQ-B-626D with wrap around
beryllium copper spring per QQ-C-533
Finish: Gold
Body: Nylon 6/6 per ASTM D4066
Threaded Brass Jacket: Per QQ-B-626D, nickel plated
Hardware: Nickel plated washer and nut
(unassembled)
Panel Thickness: Up to .218 (5.45)
RATINGS
Current: 10 amps
Breakdown Voltage: 5700 Vrms minimum
Contact Resistance: 0.004 ohms maximum
Contact-To-Panel C: 2 pF nominal
Manufactured to meet MIL-C-39024/10
PART NO.
COLOR PART NO.
COLOR
105-1041-001
White
105-1044-001
Green
105-1042-001
Red
105-1047-001
Yellow
105-1043-001
Black
105-1050-001
Blue
SILVER PLATING
APPLICATION Connection to test equipment Power supplies Electrical instruments
Avoid user injury due to misapplication. See safety advisory definitions on page 2.