1
MPB80 SERIES
The MPB80 combines high density power and other standard features
usually found in premium power systems. The low-profile package
neatly fits 1U height constraints in an industry-standard 3" X 5"
footprint. This Power Factor Corrected (PFC), multiple output
product line features overvoltage and overcurrent protection. In
addition to UL, CSA, and TüV, regulatory agency compliances
include the CE Marking and harmonic compliance to EN61000-3-2.
FEATURES
Power Factor Correction (PFC) Meets EN61000-3-2
Low-Profile Height Fits 1U Constraints
High 3.3V and 5V Current Capabilities Available
CE Marked to Low Voltage Directive
Autoranging AC Input, 85-264 VAC
Overvoltage Protection on the Main Output
DUAL AND TRIPLE OUTPUT MODEL SELECTION CHART –
UP TO 63W CONVECTION COOLED, UP TO 80W FORCED AIR COOLED (300 LFM)
MODEL
OUTPUT
VOLTAGE
+5V
+12V
+5V
+12V
-12V
+3.3V
+5V
+12V
ADJUSTMENT
RANGE
4.7V to 5.8V
Fixed
4.7V to 5.8V
Fixed
Fixed
3.0V to 3.9V
4.7V to 5.8V
Fixed
CONVECTION
COOLED CURRENT
11A/15A PK
0.5A/1A PK
7A/8.5A PK
2.5A/3A PK
0.3A/0.7A PK
7A/8.5A PK
3A/5A PK
0.4A/0.65A PK
FORCED AIR
CURRENT
15A
1A
8.5A
3A
0.7A
8.5A
5A
0.65A
LINE
TOTAL
RIPPLE & NOISE
mV (NOTE 1)
1%
1%
1%
1%
1%
1%
1%
1%
INITIAL SETTING
ACCURACY
4.9V to 5.1V
11.5V to 12.5V
4.9V to 5.1V
11.5V to 12.5V
-11.5V to -12.5V
3.27V to 3.33V
4.95V to 5.05V
10.2V to 14.0V
REGULATION
0.8%
0.5%
0.5%
1.5%
0.5%
0.7%
0.5%
1.5%
REGULATION
-4%, +2%
±5%
-4%, +6%
-7%, +13%
±4%
±2%
±2%
-15%, +17%
MPB80-2000
MPB80-3000
MPB80-3300
(Note 2)
NOTES:
1) Maximum peak-to-peak noise, bandwidth limited to 20 MHz.
2) MPB80-3300 has overvoltage protection on +3.3V and +5V outputs.
SINGLE OUTPUT MODEL SELECTION CHART –
UP TO 72W CONVECTION COOLED, UP TO 100W FORCED AIR COOLED (300 LFM)
OUTPUT
ADJUSTMENT
CONVECTION COOLED
VOLTAGE
RANGE
OUTPUT CURRENT
MPB80-1012
12V
11V to 13V
6A
MPB80-1024
24V
22V to 26V
3A
MPB80-1048
48V
46V to 50V
1.5A
NOTES:
1) Maximum peak-to-peak noise, bandwidth limited to 20 MHz.
MODEL
FORCED AIR
OUTPUT CURRENT
8.4A
4.2A
2.1A
LINE
LOAD
RIPPLE & NOISE
%p-p (NOTE 1)
1%
1%
1%
INITIAL SETTING
ACCURACY
11.94V to 12.06V
23.88V to 24.12V
47.76V to 48.24V
REGULATION
0.5%
0.5%
0.5%
REGULATION
1%
1%
1%
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
Rev. 10/2000