www.vishay.com
4
For technical questions contact: ff3cresistors@vishay.com
Document Number: 28727
Revision: 08-Mar-04
MPR24
Vishay BCcomponents
Ultra Precision Leaded Resistors
FUNCTIONAL PERFORMANCE
±
0.5 %;
±
0.25 %;
±
0.1 %
±
0.05 %;
±
0.02 %;
±
0.01 %
C
100
150
-50
0
50
70
Ambient Temperature
amb
0
0.1
0.2
W
P
Derating - Depending on Resistance Tolerances
TESTS AND REQUIREMENTS
Essentially all tests are carried out in accordance with the
following specifications:
EN 140000 / IEC 60115-1, Generic specification (includes
tests)
EN 140100 / IEC 60115-2, Sectional specification (includes
schedule for qualification approval)
CECC 40101-806, Detail specification (includes schedule
for conformance inspection)
Most of the components are approved in accordance with
the European CECC-system, where applicable. The
following table contains only the most important tests. For
the full test schedule refer to the documents listed above.
The testing also covers most of the requirements specified
by EIA/IS-703 and JIS-C-5202.
The tests are carried out in accordance with IEC 60 068 and
under standard atmospheric conditions in accordance with
IEC 60068-1, 5.3. Climatic category LCT/UCT/56 (rated
temperature range: Lower Category Temperature, Upper
Category Temperature; damp heat, long term, 56 days) is
valid.
Unless otherwise specified the following values apply:
Temperature: 15
°
C to 35
°
C
Relative humidity: 45 % to 75 %
Air pressure: 86 kPa to 106 kPa (860 mbar to 1 060 mbar).
For testing the components are mounted on a test board in
accordance with IEC 60115-1, 4.31 unless otherwise
specified.
In the Test Procedures and Requirements table only the
tests and requirements are listed with reference to the
relevant clauses of IEC 60115-1 and IEC 60068-2; a short