Output:
Current:
±12V
10A
MQFL-270-12D
Technical Specification
MQFL-270-12D ELECTRICAL CHARACTERISTICS (Continued)
Parameter
Min. Typ. Max. Units Notes & Conditions
Group A
Vin=270V dc ±5%, Iout=10A, CL=0F, free running (see
Note 10) unless otherwise specified
Subgroup
(see Note 14)
EFFICIENCY
Iout = 10A (155Vin)
85
90
%
1, 2, 3
Iout = 5A (155Vin)
86
90
%
1, 2, 3
Iout = 10A (270Vin)
84
89
%
1, 2, 3
Iout = 5A (270Vin)
83
87
%
1, 2, 3
Iout = 10A (400Vin)
81
86
%
1, 2, 3
Iout = 5A (400Vin)
77
83
%
1, 2, 3
Load Fault Power Dissipation
22
36
%
1, 2, 3
Short Circuit Power Dissipation
24
43
W
1, 2, 3
ISOLATION CHARACTERISTICS
Isolation Voltage (dielectric strength)
Input RTN to Output RTN
500
V
1
Any Input Pin to Case
500
V
1
Any Output Pin to Case
500
V
1
Isolation Resistance (input rtn to output rtn)
100
MΩ
1
Isolation Resistance (any pin to case)
100
MΩ
1
Isolation Capacitance (input rtn to output rtn)
44
nF
1
FEATURE CHARACTERISTICS
Switching Frequency (free running)
500
550
600
kHz
1, 2, 3
Synchronization Input
Frequency Range
500
700
kHz
1, 2, 3
Logic Level High
2
5.5
V
1, 2, 3
Logic Level Low
-0.5
0.8
V
1, 2, 3
Duty Cycle
20
80
%
See Note 5
Synchronization Output
Pull Down Current
20
mA
VSYNC OUT = 0.8V
See Note 5
Duty Cycle
25
80
%
Output connected to SYNC IN of other MQFL unit
See Note 5
Enable Control (ENA1 and ENA2)
Off-State Voltage
0.8
V
1, 2, 3
Module Off Pulldown Current
80
A
Current drain required to ensure module is off
See Note 5
On-State Voltage
2
V
1, 2, 3
Module On Pin Leakage Current
20
A
Imax drawn from pin allowed, module on
See Note 5
Pull-Up Voltage
3.2
4.0
4.5
V
See Figure A
1, 2, 3
RELIABILITY CHARACTERISTICS
Calculated MTBF (MIL-STD-217F2)
GB @ Tcase = 70C
2600
103 Hrs.
AIF @ Tcase = 70C
290
103 Hrs.
WEIGHT CHARACTERISTICS
Device Weight
79
g
Electrical Characteristics Notes
1. Converter will undergo input over-voltage shutdown.
2. Derate output power to 50% of rated power at Tcase = 135 C.
3. High or low state of input voltage must persist for about 200s to be acted on by the lockout or shutdown circuitry.
4. Current limit inception is defined as the point where the output voltage has dropped to 90% of its nominal value.
5. Parameter not tested but guaranteed to the limit specified.
6. Load current transition time ≥ 10 s.
7. Settling time measured from start of transient to the point where the output voltage has returned to ±1% of its final value.
8. Line voltage transition time ≥ 250 s.
9. Input voltage rise time ≥ 250 s.
10. Operating the converter at a synchronization frequency above the free running frequency will slightly reduce the converter’s efficiency and may also cause a
slight reduction in the maximum output current/power available. For more information consult the factory.
11. After a disable or fault event, module is inhibited from restarting for 300 ms. See Shut Down section.
12. All +Vout and -Vout voltage measurements are made with Kelvin probes on the output leads.
13. SHARE pin outputs a power failure warning pulse during a fault condition. See Current Share section.
14. Only the ES and HB grade products are tested at three temperatures. The C grade products are tested at one temperature. Please refer to the ESS table for
details.
15. These derating curves apply for the ES- and HB- grade products. The C- grade product has a maximum case temperature of 100 C and a maximum junction
temperature rise of 20 C above TCASE.
16. Converter delivers current into a persisting short circuit for up to 1 second. See Current Limit in the Application Notes section.