![](http://datasheet.mmic.net.cn/60000/MALCE11AE3TR_datasheet_2081670/MALCE11AE3TR_3.png)
TECHNICAL DATA SHEET
Gort Road Business Park, Ennis, Co. Clare, Ireland.
6 Lake Street, Lawrence, MA 01841
Tel: +353 (0) 65 6840044, Fax: +353 (0) 65 6822298
Tel: 1-800-446-1158 / (978) 794-1666, Fax: (978) 6890803
Website: http://www.microsemi.com
___________________________________________________________________________________________________________________________________
RF01009 Rev A, June 2010
High Reliability Product Group
Page 3 of 4
ELECTRICAL CHARACTERISTICS @ 25oC
MICROSEMI
PART
NUMBER
REVERSE
STANDOFF
VOLTAGE
VWM
(Note 1)
V
BREAKDOWN VOLTAGE
VBR @ IBR
MAXIMUM
STANDBY
CURRENT
ID @VWM
A
MAXIMUM
CLAMPING
VOLTAGE
VC @ IPP
V
MAXIMUM
PEAK PULSE
CURRENT
IPP
A
MAXIMUM
CAPACITANCE
@ 0 V
f = 1 MHz
pF
WORKING
INVERSE
BLOCKING
VOLTAGE
VWIB
V
INVERSE
BLOCKING
LEAKAGE
CURRENT
IIB @ VWIB
A
PEAK
INVERSE
BLOCKING
VOLTAGE
VPIB
V
VMIN
VMAX
mA
MLCE6.5A
MLCE7.0A
6.5
7.0
7.22
7.78
7.98
8.60
10
1000
500
11.2
12.0
100
75
10
100
MLCE7.5A
MLCE8.0A
7.5
8.0
8.33
8.89
9.21
9.83
10
1
250
100
12.9
13.6
100
75
10
100
MLCE8.5A
MLCE9.0A
8.5
9.0
9.44
10.0
10.4
11.1
1
50
10
14.4
15.4
100
97
100
75
10
100
MLCE10A
MLCE11A
10
11
11.1
12.2
12.3
13.5
1
5
17.0
18.2
88
82
100
75
10
100
MLCE12A
MLCE13A
12
13
13.3
14.4
14.7
15.9
1
5
19.9
21.5
75
70
100
75
10
100
MLCE14A
MLCE15A
14
15
15.6
16.7
17.2
18.5
1
5
23.2
24.4
65
61
100
75
10
100
MLCE16A
MLCE17A
16
17
17.8
18.9
19.7
20.9
1
5
26.0
27.6
57
54
100
75
10
100
MLCE18A
MLCE20A
18
20
20.0
22.2
22.1
24.5
1
5
29.2
32.4
51
46
100
75
10
100
MLCE22A
MLCE24A
22
24
24.4
26.7
26.9
29.5
1
5
35.5
38.9
42
39
100
75
10
100
MLCE26A
MLCE28A
26
28
28.9
31.1
31.9
34.4
1
5
42.1
45.4
36
33
100
75
10
100
MLCE30A
MLCE33A
30
33
33.3
36.7
36.8
40.6
1
5
48.4
53.3
31
28.1
100
75
10
100
MLCE36A
MLCE40A
36
40
40.0
44.4
44.2
49.1
1
5
58.1
64.5
25.8
23.3
100
75
10
100
MLCE43A
MLCE45A
43
45
47.8
50.0
52.8
55.3
1
5
69.4
72.7
21.6
20.6
100
150
10
200
MLCE48A
MLCE51A
48
51
53.3
56.7
58.9
62.7
1
5
77.4
82.4
19.4
18.2
100
150
10
200
MLCE54A
MLCE58A
54
58
60.0
64.4
66.3
71.2
1
5
87.1
93.6
17.2
16.0
100
150
10
200
MLCE60A
MLCE64A
60
64
66.7
71.1
73.7
78.6
1
5
96.8
103.0
15.5
14.6
90
150
10
200
MLCE70A
MLCE75A
70
75
77.8
83.3
86.0
92.1
1
5
113
121
13.3
12.4
90
150
10
200
MLCE80A
MLCE90A
80
90
88.7
100
98.0
111
1
5
129
146
11.6
10.3
90
150
300
10
200
MLCE100A
MLCE110A
100
110
111
122
123
135
1
5
162
178
9.3
8.4
90
300
10
200
400
MLCE120A
MLCE130A
120
130
133
144
147
159
1
5
193
209
7.8
7.2
90
300
10
400
MLCE150A
MLCE160A
150
160
167
178
185
197
1
5
243
259
6.2
5.8
90
300
10
400
MLCE170A
170
189
209
1
5
275
5.4
90
300
10
400
NOTE 1:
TVS are normally selected according to the reverse “Standoff Voltage” (V
WM) that should be equal to or greater than
the dc or continuous peak operating voltage level