![](http://datasheet.mmic.net.cn/60000/MASMCGLCE11A_datasheet_2793709/MASMCGLCE11A_3.png)
TECHNICAL DATA SHEET
Gort Road Business Park, Ennis, Co. Clare, Ireland.
6 Lake Street, Lawrence, MA 01841
Tel: +353 (0) 65 6840044, Fax: +353 (0) 65 6822298
Tel: 1-800-446-1158 / (978) 794-1666, Fax: (978) 6890803
Website: http://www.microsemi.com
________________________________________________________________________________________________________________________________
RF01002 Rev A, June 2010
High Reliability Product Group
Page 3 of 4
ELECTRICAL CHARACTERISTICS @ 25oC
MICROSEMI
PART NUMBER
Reverse
Stand-Off
Voltage
VWM
Breakdown Voltage
VBR @ IBR
Maximum
Reverse
Leakage
ID @ VWM
Maximum
Clamping
Voltage
VC @ IPP
Maximum
Peak Pulse
Current IPP
@10/1000
Maximum
Capacitance
@ 0 Volts,
f = 1 MHz
Working
Inverse
Blocking
Voltage
VWIB
Inverse
Blocking
Leakage
Current
IIB
Peak
Inverse
Blocking
Voltage
VPIB
GULL-WING
J-BEND
V
VMIN
VMAX
mA
A
V
A
pF
V
A
V
MSMCGLCE6.5A
MSMCGLCE7.0A
MSMCJLCE6.5A
MSMCJLCE7.0A
6.5
7.0
7.22
7.78
7.98
8.60
10
1000
500
11.2
12.0
100
75
10
100
MSMCGLCE7.5A
MSMCGLCE8.0A
MSMCJLCE7.5A
MSMCJLCE8.0A
7.5
8.0
8.33
8.89
10.2
9.83
10
1
250
100
14.3
13.6
100
75
10
100
MSMCGLCE8.5A
MSMCGLCE9.0A
MSMCJLCE8.5A
MSMCJLCE9.0A
8.5
9.0
9.44
10.0
10.4
11.1
1
50
10
14.4
15.4
100
97
100
75
10
100
MSMCGLCE10A
MSMCGLCE11A
MSMCJLCE10A
MSMCJLCE11A
10
11
11.1
12.2
12.3
13.5
1
5
17.0
18.2
88
82
100
75
10
100
MSMCGLCE12A
MSMCGLCE13A
MSMCJLCE12A
MSMCJLCE13A
12
13
13.3
14.4
14.7
15.9
1
5
19.9
21.5
75
70
100
75
10
100
MSMCGLCE14A
MSMCGLCE15A
MSMCJLCE14A
MSMCJLCE15A
14
15
15.6
16.7
17.2
18.5
1
5
23.2
24.4
65
61
100
75
10
100
MSMCGLCE16A
MSMCGLCE17A
MSMCJLCE16A
MSMCJLCE17A
16
17
17.8
18.9
19.7
20.9
1
5
26.0
27.6
57
54
100
75
10
100
MSMCGLCE18A
MSMCGLCE20A
MSMCJLCE18A
MSMCJLCE20A
18
20
20.0
22.2
22.1
24.5
1
5
29.2
32.4
51
46
100
75
10
100
MSMCGLCE22A
MSMCGLCE24A
MSMCJLCE22A
MSMCJLCE24A
22
24
24.4
26.7
26.9
29.5
1
5
35.5
38.9
42
39
100
75
10
100
MSMCGLCE26A
MSMCGLCE28A
MSMCJLCE26A
MSMCJLCE28A
26
28
28.9
31.1
31.9
34.4
1
5
42.1
45.5
36
33
100
75
10
100
MSMCGLCE30A
MSMCGLCE33A
MSMCJLCE30A
MSMCJLCE33A
30
33
33.3
36.7
36.8
40.6
1
5
48.4
53.3
31
28.1
100
75
10
100
MSMCGLCE36A
MSMCGLCE40A
MSMCJLCE36A
MSMCJLCE40A
36
40
40.0
44.4
44.2
49.1
1
5
58.1
64.5
25.8
23.3
100
75
10
100
MSMCGLCE43A
MSMCGLCE45A
MSMCJLCE43A
MSMCJLCE45A
43
45
47.8
50.0
52.8
55.3
1
5
69.4
72.7
21.6
20.6
100
150
10
200
MSMCGLCE48A
MSMCGLCE51A
MSMCJLCE48A
MSMCJLCE51A
48
51
53.3
56.7
58.9
62.7
1
5
77.4
82.4
19.4
18.2
100
150
10
200
MSMCGLCE54A
MSMCGLCE58A
MSMCJLCE54A
MSMCJLCE58A
54
58
60.0
64.4
66.3
71.2
1
5
87.1
93.6
17.2
16.0
100
150
10
200
MSMCGLCE60A
MSMCGLCE64A
MSMCJLCE60A
MSMCJLCE64A
60
64
66.7
71.1
73.7
78.6
1
5
96.8
103
15.5
14.6
90
150
10
200
MSMCGLCE70A
MSMCGLCE75A
MSMCJLCE70A
MSMCJLCE75A
70
75
77.8
83.3
85.0
92.1
1
5
113
121
13.3
12.4
90
150
10
200
MSMCGLCE80A
MSMCGLCE90A
MSMCJLCE80A
MSMCJLCE90A
80
90
88.7
100
98.0
111
1
5
129
146
11.6
10.3
90
150
300
10
200
MSMCGLCE100A
MSMCGLCE110A
MSMCJLCE100A
MSMCJLCE110A
100
110
111
122
123
135
1
5
162
178
9.3
8.4
90
300
10
200
400
MSMCGLCE120A
MSMCGLCE130A
MSMCJLCE120A
MSMCJLCE130A
120
130
133
144
147
159
1
5
193
209
7.8
7.2
90
300
10
400
MSMCGLCE150A
MSMCGLCE160A
MSMCJLCE150A
MSMCJLCE160A
150
160
167
178
185
197
1
5
243
259
6.2
5.8
90
300
10
400
MSMCGLCE170A
MSMCJLCE170A
170
189
231
1
5
304
4.9
90
300
10
400
NOTE 1:
TVS are normally selected according to the reverse “Stand Off Voltage” (VWM) which should be equal to or greater
than the dc or continuous peak operating voltage level.