![](http://datasheet.mmic.net.cn/390000/MZ4625_datasheet_16823904/MZ4625_39.png)
1N5333B through 1N5388B
Motorola TVS/Zener Device Data
6-135
5 Watt Surmetic 40 Data Sheet
Devices listed in bold, italic are Motorola preferred devices.
ELECTRICAL CHARACTERISTICS — continued
(TA = 25
°
C unless otherwise noted, VF = 1.2 Max @ IF = 1 A for all types)
JEDEC
Type No.
(Note 1)
Nominal
Zener
Voltage
VZ @ IZT
Volts
(Note 2)
Test
Current
IZT
mA
Max Zener Impedance
Max Reverse
Leakage Current
Max
Surge
Current
ir, Amps
(Note 3)
Max Voltage
Regulation
VZ, Volt
(Note 4)
Maximum
Regulator
Current
IZM
mA
(Note 5)
ZZT @IZT
Ohms
(Note 2)
ZZK @ IZK = 1 mA
Ohms
(Note 2)
IR
μ
A
VR
Volts
@
1N5383B
1N5384B
1N5385B
1N5386B
1N5387B
1N5388B
150
160
170
180
190
200
8
8
8
5
5
5
330
350
380
430
450
480
1500
1650
1750
1750
1850
1850
0.5
0.5
0.5
0.5
0.5
0.5
114
122
129
137
144
152
1.1
1.1
1
1
0.9
0.9
3
3
3
4
5
5
31.6
29.4
28
26.4
25
23.6
NOTE 1. TOLERANCE AND TYPE NUMBER DESIGNATION
The JEDEC type numbers shown indicate a tolerance of
±
5%.
NOTE 2. ZENER VOLTAGE (VZ) AND IMPEDANCE (ZZT & ZZK)
Test conditions for zener voltage and impedance are as follows: IZ is applied 40
±
10 ms prior
to reading. Mounting contacts are located 3/8
″
to 1/2
″
from the inside edge of mounting clips
to the body of the diode. (TA = 25
°
C +8, –2
°
C).
NOTE 3. SURGE CURRENT (ir)
Surge current is specified as the maximum allowable peak, non-recurrent square-wave cur-
rent with a pulse width, PW, of 8.3 ms. The data given in Figure 6 may be used to find the
maximum surge current for a square wave of any pulse width between 1ms and 1000 ms by
plotting the applicable points on logarithmic paper. Examples of this, using the 3.3 V and
200 V zeners, are shown in Figure 7. Mounting contact located as specified in Note 3. (TA =
25
°
C +8, –2
°
C.)
NOTE 4. VOLTAGE REGULATION (
VZ)
Test conditions for voltage regulation are as follows: VZ measurements are made at 10% and
then at 50% of the IZ max value listed in the electrical characteristics table. The test current
time duration for each VZ measurement is 40
±
10 ms. (TA = 25
°
C +8, –2
°
C). Mounting contact
located as specified in Note 2.
NOTE 5. MAXIMUM REGULATOR CURRENT (IZM)
The maximum current shown is based on the maximum voltage of a 5% type unit, therefore,
it applies only to the B-suffix device. The actual IZM for any device may not exceed the value
of 5 watts divided by the actual VZ of the device. TL = 75
°
C at 3/8
″
maximum from the device
body.
NOTE 6. SPECIALS AVAILABLE INCLUDE:
Nominal zener voltages between the voltages shown and tighter voltage tolerance such as
±
1% and
±
2%. Consult factory.
TEMPERATURE COEFFICIENTS
Figure 2. Temperature Coefficient-Range
for Units 3 to 10 Volts
Figure 3. Temperature Coefficient-Range
for Units 10 to 220 Volts
VZ, ZENER VOLTAGE @ IZT (VOLTS)
10
8
6
4
2
0
–2
3
4
5
6
7
8
9
10
RANGE
300
200
100
50
30
20
10
5
0
20
40
60
VZ, ZENER VOLTAGE @ IZT (VOLTS)
80
100
120
140
160 180
200 220
θ
V
(
°
C
θ
V
(
°
C
RANGE