OP186
–6–
REV. 0
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection.
Although the OP186 features proprietary ESD protection circuitry, permanent damage may
occur on devices subjected to high energy electrostatic discharges. Therefore, proper ESD
precautions are recommended to avoid performance degradation or loss of functionality.
WARNING!
ESD SENSITIVE DEVICE
ABSOLUTE MAXIMUM RATINGS
Supply Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +16 V
Input Voltage . . . . . . . . . . . . . . . . . . . . . . . GND to V
S
+ 10 V
Differential Input Voltage
Output Short-Circuit Duration to GND . . . . . . . . . Indefinite
Storage Temperature Range
RT Package . . . . . . . . . . . . . . . . . . . . . . . –65
°
C to +150
°
C
Operating Temperature Range
OP186G . . . . . . . . . . . . . . . . . . . . . . . . . . –40
°
C to +125
°
C
Junction Temperature Range
RT Package . . . . . . . . . . . . . . . . . . . . . . . –65
°
C to +150
°
C
Lead Temperature Range (Soldering, 60 sec) . . . . . . .+300
°
C
1
. . . . . . . . . . . . . . . . . . . . . .
±
3.5 V
NOTES
1
Stresses above those listed under Absolute Maximum Ratings may cause perma-
nent damage to the device. This is a stress rating only; functional operation of the
device at these or any other conditions above those listed in the operational sections
of this specification is not implied. Exposure to absolute maximum rating condi-
tions for extended periods may affect device reliability.
2
For supplies less than
±
5 V the differential input voltage is limited to the supplies.
ORDERING GUIDE
Temperature
Range
–40
°
C to +125
°
C
Package
Description
Package
Option
Model
OP186GRT
5-Lead SOT-23
RT-5
Package Type
u
JA1
u
JC
Units
°
C/W
5-Lead SOT-23 (RT)
230
140
NOTE
1
θ
JA
is specified for worst case conditions, i.e.,
θ
JA
is specified for device in socket
for SOT packages.