Passing Criteria
Passing criteria for the First Level Lightning Surge Test and the First Level AC Power
Fault Test is that the EUT will not be damaged and it will operate as intended after the
stress is removed. Passing criteria for the Second Level Lightning Surge Test and
Second Level AC Power Fault Test is that the EUT may be damaged, but it may not
become a fire, fragmentation, or electrical safety hazard. Passing criteria for the
Current Limiter Test is that the EUT may be damaged, but it may not exceed the
acceptable time/current criteria (i.e., it can not cause the wiring simulator in Figure 4-2
to open) nor become a fire, fragmentation, or electrical safety hazard.
The indicator used in measuring fire, fragmentation, and electrical safety hazards is a
bleached, untreated cotton cheesecloth which is wrapped around the EUT.
Compliance with testing is determined by the absence of ignition, charring, and the
ejection of molten material or fragments.
Lightning Fault Immunity Test
Metallic Voltage
- is defined as the potential difference between Tip and Ring. Metallic
voltages occur when there is an imperfect balance on the twisted pair. This imbalance
typically arises due to unmatched components, but can also occur when longitudinal
surges are converted to metallic surges due to asymmetrical operation of over-voltage
protectors.
Longitudinal Voltage
- is defined by Bellcore as half of the sum of the potential
difference seen between the Tip conductor and earth ground and the Ring conductor
and earth ground. During transient activity, damaging voltages are propagated over
the phone lines raising the potential difference of each line with respect to earth
ground. It is this potential difference that is often attributed to failed network equipment
and is simulated in Tests 1, 2, 3, and 5 in Table 4-2.
Test 4 in Table 4-2 simulates transients that are coupled to the network equipment via
ground conductors. These transients occur when nearby lightning strikes produce
large surge currents which generate excessive voltage due to the resistive path of the
protector and power grounds.
First Level Lightning Surge Test
To pass the First Level Lightning Surge Test, the EUT must be undamaged and
continue to operate properly after the stress is removed. This is referred to as passing
operationally
. The conditions for the First Level criteria are shown in Table 4-2. The
applicants have the option to submit their equipment to meet surges 1, 2, 4 and 5 or
surges 3, 4, and 5.
相關PDF資料
PDF描述
P2202AA 16 PIN, 1.75KB FLASH, 64B RAM, 6 I/O, 8MHZ INTERNAL OSCILLATOR, -40C to +125C, 16-QFN, T/R
P2202AARP 14 PIN, 4KB FLASH, 128 RAM, 12 I/O, -40C to +85C, 16-QFN, T/R
P2202AB 14 PIN, 4KB FLASH, 128 RAM, 12 I/O, -40C to +85C, 14-TSSOP, T/R
P2202ABRP SIDAC|130V V(BO) MAX|800MA I(S)|TO-220VAR
P2202AC SIDAC|130V V(BO) MAX|800MA I(S)|TO-220VAR
相關代理商/技術參數(shù)
參數(shù)描述
P2-201L 制造商:Johnson Electric / Parlex Corporation 功能描述:
P22-020 制造商:未知廠家 制造商全稱:未知廠家 功能描述:Analog IC
P22-020I 制造商:未知廠家 制造商全稱:未知廠家 功能描述:Analog IC
P22-020K 制造商:未知廠家 制造商全稱:未知廠家 功能描述:Analog IC
P22-020K2 制造商:未知廠家 制造商全稱:未知廠家 功能描述:Analog IC